What size air admittance valve do I need?

Author: Carson Green  |  Last update: Tuesday, May 26, 2026

AAVs are typically available with 1 ½”, 2”, 3” and 4” adapter connections. The adapter size is based on the diameter of the vent pipe it is being installed on. Generally, a vent should be sized to be half the pipe diameter of the drain it is serving (refer to local codes for specific vent size recommendations).

Can you oversize an air admittance valve?

Five DFUs for the bathroom group, three for the washing machine and one for the laundry tub. This example needs an AAV of at least nine DFUs. It is acceptable to oversize an AAV; however, an undersized AAV will not allow the plumbing system to breathe properly.

Are there different size air admittance valves?

Sure-Vent® Air Admittance Valves comply to ASSE Standard 1050 and 1051 and IAPMO listed sizes. Oatey Sure-Vent® AAVs are available in four sizes ranging from 8 Stack/24 Branch DFU to 160 Stack/500 Branch DFU.

How high should AAV be above trap?

Individual and branch-type AAVs shall not be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented. See Figure 4, Examples 1, 2 and 3. AAVs shall be accessible, should replacement be required.

What is the downside of the air admittance valve?

The other potential problem with using an AAV instead of a vent pipe is that if you ever get a blockage in the system that prevents the gasses from being pushed down into the sewer, those gases will have nowhere else to go.

Air admittance valves for plumbing venting explained, [just over 4 minutes]

What are the rules for air admittance valves?

The short answer is a minimum of 200mm above any water entry point. So if you imagine your soil pipe run, then durgo valve / AAV must be fitted above the highest connection to the soil pipe from any sink, bath or toilet that is connected to it.

What is the life expectancy of an air admittance valve?

Air admittance valves have a typical life expectancy of 20-30 years, so if you start to have issues with sewer gases or smells being released around your sink or in the attic-wherever installed- the air admittance valve could be faulty or failed and should be replaced as soon as possible.

Does the AAV go before or after the trap?

Air admittance valves are typically placed between the P-trap of a fixture and the drain line. They're usually mounted on one leg of a sanitary tee, with the other leg going to the drain. The unit must be placed per local codes and the manufacturer's instructions.

Where are air admittance valves not allowed?

Air admittance valves are not permitted in spaces where pressure conditions adversely affect the valve's operation. They are also not allowed in concealed wall and ceiling spaces used as plenums as part of an air distribution system that is under negative or positive pressure.

Does an air admittance valve stop smelling?

Air admittance valves often feature rubber seals, to help create a complete seal, increasing the effectiveness of the valve and preventing any odours from escaping through small gaps.

What happens if you oversize a valve?

Again, an oversized valve will result in a high stroke count, which over time will wear down your valve trim and packing much faster than it should under normal operation. This can lead to deterioration of the trim, resulting in poor performance and potential environmental issues.

How many fixtures can be on a 2 inch vent?

Under the Uniform Plumbing Code, a 2" vent can handle 24 fixture units(F.U). In a residence, a lavatory sink= 1.0 F.U., bathtub/shower= 2.0 F.U. and a toilet 1.6 gallon or less= 3.0 F.U, greater than 1.6 gallon= 4.0 F.U.

Do air admittance valves wear out?

Remember that these valves should last anywhere from 20 to 30 years, so if they are only lasting for a couple of years, there may be some problems that need addressing.

Where should I place my air admittance valve?

The AAV should be located a minimum of four inches above the horizontal branch wall tube. » Securing AAV: Measure and cut the PVC pipe appropriately. Solvent-weld the pipe into the adaptor using PVC cement, such as the Oatey® Heavy Duty Clear PVC Cement, which can be used for all PVC pipe and fittings.

What is the difference between an air admittance valve and a cheater vent?

Automatic air vents are spring type devices often referred to as in-line or cheater vents, while air admittance valves have no spring. Air admittance valves are more expensive and are approved in many jurisdictions where in-line and cheater vents are not because of their moving parts (springs).

Why are studor vents illegal?

The Studor vent lets that air to be sucked in the pipe during water flow but doesn't let sewer gas escape out. Code is the thing that determines pipe size and also water flow. Hence no studor vents are permitted to toilets because more air is required to keep water flow going with more waste added to the toilet.

Can water come out of an air admittance valve?

In order for a liquid to come out, air must come in. All DWV plumbing systems require at least one vent penetration through the roof line, which allows air to enter the system, while also permitting sewer gas to escape.

Can all drains tie into one vent?

A horizontal wet vent could have as few as two fixtures or as many as ten fixtures but not more than two fixtures of any type can be connected to the system. Each wet vented fixture drain shall connect independently to the horizontal wet vent.

What is the problem with the air admittance valve?

The first indication you may get that there is a problem is the symptoms we mentioned at the outset – bad odours in the house, gurgling and slow-draining pipes. If this happens immediately after the valve has been installed, check that it has been fitted correctly.

What height should an air admittance valve be installed?

External Air Admittance Valves will allow the installation of an external soil pipe within 3 metres of any opening and terminate at the same height as if it were installed internally, i.e. 200mm (minimum) above the highest wet entry point to the soil vent pipe.

Are cheater vents legal?

Sometimes called "cheaters," these tubular, spring-loaded $5 vents are rated for only 1/2 DFU (drainage fixture unit), and are not allowed under most building codes.

In what states are air admittance valves legal?

They are not illegal in California as a state because California Plumbing Code allows "Engineered Vent Systems" see Section 911.0.

How high should an air admittance valve be above a trap?

AAV location

An AAV should be located within the maximum developed length permitted for the vent. It must be located a minimum of 4” above the horizontal branch drain, 6” above any insulation material and within 15 degrees of vertical.