Will a Txv rated for R-22 work with R-410A?

Author: Roy Abbott Sr.  |  Last update: Sunday, December 7, 2025

"Hey Dan, do I need to change the TXV valve when switching the outdoor condenser from R-22 refrigerant to R410A?" Yes, you are going to have to change out the TXV. Why? Well, R410A works at a different temperature and a different pressure than R-22. If you don't change it then it's not going to boil off correctly.

What is the difference between R-22 and R-410A Txv?

R22 and R410A Systems Selected

The two systems comprised the same evaporator and condenser. The main differences between the compared systems were the compressor, lubricant, and refrigerant. The piping arrangement included different thermostatic expansion valves (TXVs) and liquid line filters.

What happens if you put R-22 in a 410A system?

If you use R-22 in the same system as R-410a, the compressor is going to be trying to work two different fluids through the same coils as both refrigerants respond differently to different mechanical situations. As you might imagine, this isn't going to go well for your air conditioner or heat pump.

Can you reuse R-22 line set for R-410A?

So what the manufacturer recommends, the best option, is if you're going to go from an R22 unit to an R410 unit, that you should have your line set replaced at the same time. So everything is new. There's no contamination, there's no possibility of contamination.

Are R-410A and R-22 refrigerants interchangeable and compatible with each other?

The refrigerants have very different heat-transfer properties and use chemically incompatible lubricating oils, so they aren't interchangeable and can't be mixed. Transitioning one unit to the next could require replacing the compressor, evaporator and condenser, along with potentially replacing their copper lines.

410a txv on a r22 system

Can you mix R-22 with any other refrigerant?

Mixing R22 with R407C or any other refrigerant. According to the 609 EPA rule, mixing refrigerants is illegal and anybody caught doing so will be heavily fined.

Is R-410A an acceptable drop in replacement for R-22?

R-22 uses simple mineral oil, non-toxic, safe, stable, etc. while R-410a uses a somewhat exotic Poly o Ester (POE) oil typically found in jet turbine engines. The refrigerant used MUST match the oil present in the system, which is one reason why you can't replace the R-22 with R410a in a system.

Can you use R-410A pipes for R-22?

The operational pressure of the refrigerant R410A becomes higher compared to R22. In the worst case, a lack of compressive strength may lead to piping explosion.

How much does it cost to convert R-22 to R-410A?

How much will an R-22 to R-410A conversion cost? The actual cost will depend on many things, including where you live, but most of the time R-22 conversions start at around $2,000 and go up from there. The higher end of that range is somewhere around $4,500 to $4,600.

Can I use a 410A coil with a R-22 condenser?

I think it is important to remember that R22 and r410a are made of the same chemicals just in different ratios. Though the oils are different, Mineral and Polyester are not going to contaminate each other. They will not mix but that does not cause a problem.

Can you flush R-22 to R-410A?

When you replace an air conditioner or heat pump and upgrade from R-22 to R-410A, the ideal solution is to replace your refrigerant lines. This is because the mineral oil used in R-22 systems is not compatible with the new R-410A refrigerant and oil.

What refrigerant is compatible with R-22?

  • Also Acceptable: R427A, R404A, R407C.
  • Also Acceptable: R422D, R427A.
  • * Note: If compressor is being replaced as part of the service call on a small system, install a POE compressor and retrofit to the better capacity/lower GWP blend.

Does R-410A get as cold as R-22?

In fact, R410A can cool a room slightly faster with less energy. Efficient performance is a significant benefit of R410A. However, it works the same way as R22 in absorbing heat to provide cooling. But R410A doesn't make a room any colder than its predecessor.

Will a R-22 Txv work with 410A system?

"Hey Dan, do I need to change the TXV valve when switching the outdoor condenser from R-22 refrigerant to R410A?" Yes, you are going to have to change out the TXV. Why? Well, R410A works at a different temperature and a different pressure than R-22. If you don't change it then it's not going to boil off correctly.

Are txv interchangeable?

TXVs used in air conditioning units and heat pumps are interchangeable as long as they are the same size and for the same refrigerant. However, it is recommended to follow the manufacturer's specifications and guidelines to ensure proper operation and efficiency.

What happens if you put 410A in a R-22 system?

The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur.

Can you use the same line set from R-22 to 410A?

To retrofit an R-22 system with R-410A system your line set must not be more than 25-50 feet in total distance. If the line set is longer than this, you will have to replace the line set with larger lines.

Can you switch from R-22 to R-410A?

You cannot just switch refrigerants because R410-A and R-22 have different chemical properties. R410-A operates at a higher pressure. If you put R410-A into an R-22 system, the parts will rupture due to the increased force.

Will R-410A be phased out?

The impending phaseout of R-410A, a widely used refrigerant in HVAC systems, marks a huge shift for homeowners and the HVAC industry. Set to take effect on December 31, 2024, this change is driven by global efforts to reduce greenhouse gas emissions and comply with environmental regulations.

How much higher is the pressure of R-410A than R-22?

Tube-side materials in R-410A coils need to be thicker due to the higher operating pressures associated with R-410A relative to R-22. We're not arguing that there's not a difference in operating pressure between the two. There is – roughly 130 PSI for R-410A evaporators compared to about 70 for R-22.

Can R-454B be retrofitted into existing R-410A or R-22 systems?

ACHR NEWS: As a mildly flammable refrigerant, R-454B can't be retrofitted into existing R-22 and R-410A systems.

Will a bigger condenser make a difference?

A bigger ⁢condenser ensures a‌ greater heat exchange surface – ‌aiding in rapid cooling, reduced strain on the mechanical components, and enhanced dehumidification ‍- all of which translate into prompt and efficient cooling for our comfort.

What is a good replacement refrigerant for R22?

An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting hydrofluorocarbon (HFC) replacement for R-22.

What refrigerant is being phased out in 2024?

In the first half of 2024 we'll phase out our R-410A dedicated models and introduce -01 refrigerant versatile models, compatible with both R-410A and R-454B refrigerants.