Why does the flame in my gas fireplace keep going out?

Editorial team Published on

Other reasons your gas fireplace may keep going out include a cracked gas line, a faulty thermopile, or a blocked chimney. A cracked gas line may be caused by corrosion of the pipe material to the line. A faulty thermocouple may need to be replaced if it is not sending the correct signals to your gas valve.

How to fix a gas fireplace that keeps going out?

Pilot Light: Start by checking the pilot light. If it is out, resetting it could be all you need to fix the problem. Thermocouple/Thermopile/Oxygen sensor: Next, check each of these sensors to make sure they are functioning properly. Start with the thermopile to see if the valve is letting gas in.

How to tell if a gas fireplace thermocouple is bad?

If the pilot flame ignites but goes out after you release the gas control knob, the cause may be a dirty or defective thermocouple. If the gas is on but the flame will not ignite at all, a pilot tube obstruction is the most likely issue.

How long do gas fireplaces usually last?

How long do gas fireplaces last with proper maintenance? Even when well-maintained, most gas fireplaces have a lifespan of about 15 to 20 years. Here are some signs it's time to consider a replacement.

What causes a gas fireplace to not stay lit?

Pilot Light Issues: This is the most frequent offender. If the pilot flame is too weak or improperly positioned, it cannot heat the sensors enough to keep the gas valve open. Dirty Fireplace Burner Assembly: Dust, soot, or spider webs can clog the burner ports.

Gas Logs: Flame Won't Stay On - Why?

How much does it cost to replace a thermocouple on a gas fireplace?

Relighting is typically inexpensive unless the thermocouple requires replacement, which can range between $120 and $300. Ignition Problems: Often caused by faulty igniters or control valves, ignition issues may cost from $150 to $600, depending on the components needing replacement.

What is the most common problem with a gas fireplace?

14 Common Gas Fireplace Problems & What to Do

  • Unusual Odors. ...
  • The Pilot Light is Out. ...
  • Ignition Failure. ...
  • Cloudy or Hazy Glass. ...
  • Not Enough Fuel. ...
  • Dead Remote Control Batteries. ...
  • Wall Switch Turned Off. ...
  • Pilot Light Not Staying On.

What's the average cost to replace a gas fireplace?

Gas Fireplace: $3,500-6,500 (New construction), or $4,000-8,000 (remodel) Installing a gas fireplace either involves starting from scratch (new construction, addition, etc.), or removing an already existing fireplace and putting a new fireplace in its place.

What is the 2 / 10 rule for fireplaces?

Explained, the chimney pipe must be a minimum of three feet above the roof but also two feet taller than anything within ten feet. The portion of the rule stating the pipe needs to be 2 feet above anything within 10 feet is where most people get confused.

Can a dirty pilot light affect the thermocouple?

A healthy pilot flame should be a crisp, steady blue, engulfing the top third of the thermocouple. A weak, yellow, or wavering flame often indicates a dirty pilot orifice or a gas supply issue, preventing the thermocouple from getting hot enough to function.

What are the symptoms of a bad thermocouple?

A bad furnace thermocouple often causes the pilot light to go out repeatedly or prevents the furnace from staying on at all. Common warning signs include a furnace that won't ignite, a pilot light that won't stay lit, frequent shutdowns, or no heat even though the thermostat is calling for warmth.

Is it normal for a gas fireplace to go out?

Yes, up to a point. Gas fireplaces are built with multiple safety features designed to automatically shut the system down when something isn't operating correctly. These protections help prevent issues such as gas leaks, carbon monoxide buildup, overheating, and improper combustion.

Can I replace my gas fireplace with a new one?

However, like all appliances, a gas fireplace doesn't last forever. If you're considering upgrading your fireplace or need to replace your old one, it's important to weigh the safety, efficiency, and cost aspects of gas fireplace replacement.

Does a gas fireplace raise your gas bill?

The cost depends on several factors, including fuel type, heat output, and regional gas prices. On average, the cost of running a gas fireplace ranges from $0.30 to $1.50 per hour. If used for about four hours a day, this can add $36 to $180 to your monthly energy bill.

How do you fix a gas fireplace that keeps going out?

Clean your Gas Fireplace

There are also safety mechanisms that kick in to stop the pilot flame from lighting, and the gas from filling the chamber. This may happen if temperatures are too cold or if there is too much carbon buildup. Use fine-grit sandpaper and a microfiber cloth to clean these parts.

When to worry about a gas fireplace?

A weak or yellow flame might indicate a problem and should be addressed by a professional. If you get a whiff of gas near your fireplace, turn off the fireplace immediately, open windows to ventilate the area and contact a professional to get a full inspection.

Can you sleep in the same room as a gas fire?

Sleeping in the same room as an open flued gas appliance (back boiler or gas fire) contravenes the gas safety regulations and puts your life in danger.

How do I unclog a thermocouple?

Steps for Furnace Thermocouple Cleaning

  1. Turn Off Power and Gas Supply. ...
  2. Remove from Burner Assembly. ...
  3. Blow away Debris. ...
  4. Scrub Corroded Areas. ...
  5. Rinse and Dry. ...
  6. Inspect Conditions. ...
  7. Reattach and Restore Gas/Power. ...
  8. Why does my pilot light keep going out?

How to clean a clogged gas fireplace?

Vacuum Away Dust and Cobwebs

Use a hose attachment vacuum to clean each rock's side. Once the rocks are clean, vacuum all the corners of the fireplace box to capture dust, cobwebs, and insects. Use an old cloth to wipe down the pilot light and gas line components.

How long do gas fireplace thermocouples last?

Thermocouple Lifespan

A thermocouple usually lasts 3-5 years on a regularly used standing-pilot system. Some last longer, but once they begin to weaken you'll see the classic symptom: the pilot won't stay lit unless you hold the knob.

← Previous article
What angle should gutters fall?
Next article →
Why is my Fireangel carbon monoxide alarm blinking green light?