Sensors should be located near the floor for gases or vapors three or four times heavier than air. They should be installed near the ceiling or roof to detect lighter-than-air gases.
Propane is more dense than air, so propane detectors must be near the floor or lowest point of the living space. Natural gas is lighter than air, so detectors for it should be on the ceiling.
Natural gas is lighter than air. This means that if there is a natural gas leak, the gas will rise towards the ceiling. This is why the natural gas alarm should be installed within 4 to 12 inches of the ceiling.
Heavier than air gases should typically be detected 6 in / 15 cm (sometimes 12 in / 30 cm) from the floor. Lighter than air gas sensors should typically be placed on or near the ceiling, and gases which have a density close to that of air should have sensors installed in the "breathing zone".
Propane is more dense than air, so propane detectors must be near the floor or lowest point of the living space. Natural gas is lighter than air, so detectors for it should be on the ceiling.
Place sensors in areas where air currents are likely to produce the highest gas concentration, including areas where gas buildup is likely, such as corners or stopping points of gas-releasing moving devices. Factor in the monitored gas's vapor density when compared to air.
Carbon monoxide is lighter than air. It also rises with warm air, so the United States Environmental Protection Agency (EPA) recommends placing a carbon monoxide detector on a wall about five feet above the floor or about eye level. You can put them on the ceiling, too.
You can choose to not have the natural gas detector installed. However, the detector can provide valuable early warning of a gas leak emergency before it develops into a more serious situation, possibly involving a fire or an explosion. This could result in property damage, serious injuries, or death.
Natural gas is lighter than air, so it will rise and disperse if allowed to vent freely. Although rare, natural gas leaks can be dangerous and result in fire, explosions, injury or death. If you suspect a leak, call 1-800-ALLIANT (800-255-4268) immediately.
It is best to install a gas detector in every room where gas-consuming appliances are installed.
We recommend the Kidde Nighthawk Carbon Monoxide and Explosive Gas Detector as the best overall gas leak detector. It detects a wide variety of explosive gases (including propane and natural gas), along with carbon monoxide, and it has two power sources for extra redundancy.
To find out if your land has oil, you can hire a professional to conduct an oil and gas assessment. This assessment will involve drilling a few test wells on your property to see if any oil or gas is present.
Natural gas detectors can alert you and your family of odorless and dangerous leaks. They may not be as common on the list of must haves for the home such as a smoke detector or fire extinguisher, but these devices are worth serious consideration and can detect potentially serious situations.
7. Readings must be above 19.5% O2 and below 23.5% O2, 10% LEL, 25 ppm CO, and 10 ppm H2S for legal entry into a space. EHS strongly recommends that individuals not enter atmospheres containing more than 21.5% oxygen, less than 20.5% oxygen, or more than 5% LEL, 10 ppm CO or 5 ppm H2S.
If you smell a sulfur or rotten-egg-like odor, you could have a gas leak. Natural gas is naturally colorless and odorless. We add an odorant called mercaptan to natural gas, which gives it a distinctive smell. In some cases, you can also identify natural gas by sight or sound.
Install your natural gas detectors in locations close to sources of natural gas. This includes, placing them in any room with windows or a gas appliance such as your kitchen and your basement. When adding to a room with windows, be sure to position natural gas detectors higher than all doors and windows.
If there is a gas smell but no leaks, it could be the lingering propane odor due to poor ventilation or it coming from your neighbor. The dirty sewage system, contaminated well, or rotten garbage (like veggies, dead animals, residual foods, etc.) might also be the source of the smell.
In conventional natural gas deposits, the natural gas generally flows easily up through wells to the surface.
Sensors for heavier-than-air gases should generally be positioned 6 inches (15 cm) to 12 inches (30 cm) from the ground, as these gases tend to settle near the floor. For lighter-than-air gases, sensors are best placed near the ceiling or on high surfaces as these gases rise.
Where a fuel-gas-burning appliance is installed within a dwelling, the gas alarm must be installed in the same room as the appliance. The alarm must be located at least 3 feet, but not more than 10 feet from the appliance, measured horizontally. The gas alarm must be installed on either the ceiling, or a wall.
According to scientists at the National Institute for Occupational Safety and Health (NIOSH), direct reading instruments for gaseous exposure assessment should measure within ± 25% of the true concentration of the target analyte with 95% certainty.
A carbon monoxide detector should not be placed within fifteen feet of heating or cooking appliances or in or near very humid areas such as bathrooms. For more information about carbon monoxide safety, visit the National Fire Protection Association.
The DeNova Detect 10-Year 100% Battery-Powered Natural Gas Alarm offers superior performance with revolutionary Micro-Electromechanical System (MEMS) sensor technology. What to Look for In a Natural Gas Alarm? The fastest Natural Gas Alarm available with a 10% LEL alerting you to emergencies 11 minutes sooner.