An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting
The primary replacement refrigerant for R-22 is R-410A. R-410A is a hydrofluorocarbon (HFC) that does not deplete the ozone layer and has a higher efficiency compared to R-22.
The information below will try to dispel some of these myths. Arkema recommends using Forane® 427A (R427A) - The EASY RETROFIT™ for your r-22 retrofit solution. When it comes to drop-ins, the truth is that there are none. The hope of “drop-in” refrigerants has become common over the years.
Since 2010, the most common R-22 replacement was R-410A, a refrigerant without the ozone-depleting qualities of R-22. Read this article on the refrigerant transition for a more thorough explanation of the reasoning and science behind the change.
The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur. Mixing refrigerants is not an option either. This will contaminate the system, and the R22 will not evaporate under the higher suction pressure that R410A requires.
If you use R-22 in the same system as R-410a, the compressor is going to be trying to work two different fluids through the same coils as both refrigerants respond differently to different mechanical situations. As you might imagine, this isn't going to go well for your air conditioner or heat pump.
Freon MO99 is the gold standard for R-22 alternatives and was developed by the same scientists who engineered Freon R-22. The benefits of Freon MO99 include: Capacity — The ability of Freon MO99 to heat or cool a given space is closer to Freon R-22 than any other refrigerant on the market.
R-410A PHASE-DOWN TIMELINE
We will reach a 70% decrease by 2029. In 2034, we will see 80% less R-410A being produced than it is today, and the phase-down will end in 2036 with another 5% reduction.
How much will an R-22 to R-410A conversion cost? The actual cost will depend on many things, including where you live, but most of the time R-22 conversions start at around $2,000 and go up from there. The higher end of that range is somewhere around $4,500 to $4,600.
R-407C should be used only in systems that currently use R-22. It should not be mixed with R-22 or any other refrigerant. 5. The capacity of the existing R-22 thermal expansion valve (TEV) will be approximately the same when using R-407C.
Freon™ MO99 can be used to retrofit R-22 heat pumps .
* Forane® 427A is intended as a retrofit in systems originally designed for R-22. Therefore, how the system was running on R-22 will be a guide or target for how the system should run on R-427A. Compared to R-22, expect 0-5 psi lower on the suction side and 0-10 psi higher on the discharge.
The best replacement for R-22 Freon is usually R-407c. It has a very low loss in capacity (0 – 5%) relative to R-22 and is less expensive than many other R-22 replacement refrigerants. If a system has R22 in it already you cannot use a replacement refrigerant to simply add to the R22.
No, the compressor will fail. These two refrigerants have very different properties. One of R22 and R134a is high pressure and the other is low pressure. They don't mix chemically and don't have the same boiling point, leading to inefficiencies and eventual compressor failure.
As a solution, there are two alternative refrigerants used as substitute refrigerant for R22, namely R290 and R32. The R290 is widely used as working fluid in A/C system of Europe countries; meanwhile in Japan and South East countries, R32 is utilized as substitute refrigerant for R22 and R410A (Yu et al., 2010).
What refrigerant will replace R-410A in 2025? For whole-home systems, Lennox has chosen 2025 Compliant Refrigerant R-454B due to its excellent performance for ducted systems and zero ozone depletion potential. For mini-splits, we selected R-32, designed to optimize efficiency and reliability in ductless systems.
Changes to the Dangerous Goods Legislation, effective in 2021, has new categories for A2L refrigerants. R32 is a synthetic greenhouse gas. If released to the atmosphere it can contribute to climate change. R32 is a flammable refrigerant.
You cannot just switch refrigerants because R410-A and R-22 have different chemical properties. R410-A operates at a higher pressure. If you put R410-A into an R-22 system, the parts will rupture due to the increased force.
It is possible to use a different type of refrigerant inside an R-22 system. There are “drop-in” refrigerants that serve exactly this purpose. When someone has an R-22 leak, it's possible to remove all the R-22 from the system and replace it with a drop-in refrigerant.
ACHR NEWS: As a mildly flammable refrigerant, R-454B can't be retrofitted into existing R-22 and R-410A systems.
As of January 1, 2020, production and import of R22 refrigerant will be illegal in the United States. Of course, continued use of your air conditioner (AC) or heat pump system using R22 refrigerant is allowed.
Of all the "no oil change" replacement refrigerants, Freon™ MO99™ offers the closest performance match to R-22.
When you replace an air conditioner or heat pump and upgrade from R-22 to R-410A, the ideal solution is to replace your refrigerant lines. This is because the mineral oil used in R-22 systems is not compatible with the new R-410A refrigerant and oil.
No. You can't do that. It probably wouldn't work. Even though you put a compressor in there that's R410A, the rest of condenser probably isn't tested and rated for operating at R410A pressures because R410A has to operate at a higher pressure.