What refrigerant is replacing 410A?

Author: Erick Waelchi  |  Last update: Monday, September 22, 2025

The replacements for R-410A are the two A2Ls, Forane® R-32 and R-454B. Forane® R-32 can be used in new equipment designed specifically for mildly flammable refrigerants as a replacement for R-410A equipment.

What will R-410A be replaced with?

What is the replacement for R-410A? A lower GWP replacement for R-410A is Forane® R-32. Forane® 32 is a stand-alone third generation refrigerant for new residential and light commercial air conditioning systems, heat pumps and other HVAC applications.

What replaces 410A in 2025?

Air conditioner and heat pump manufacturers are rolling out new refrigerants to comply with EPA guidelines. Starting in January 2025, no new HVAC systems will use R-410A refrigerant. Instead, most residential systems will use either R-32 or R-454B refrigerant, both of which have a comparably lower environmental impact.

Can I replace R-410A with R-454B?

R-454b is a drop-in replacement for R-410a, so equipment doesn't have to be redesigned. It's about 60% R32.

Is R32 replacing R-410A?

R32 is not suitable as a drop-in replacement for R410A and must only be used in systems specifically designed for R32.

Refrigerants 410a OUT! R32 IN! Here's Why!

Why is R32 refrigerant banned?

Changes to the Dangerous Goods Legislation, effective in 2021, has new categories for A2L refrigerants. R32 is a synthetic greenhouse gas. If released to the atmosphere it can contribute to climate change. R32 is a flammable refrigerant.

How long will R410A be available?

R-410A PHASE-DOWN TIMELINE

We will reach a 70% decrease by 2029. In 2034, we will see 80% less R-410A being produced than it is today, and the phase-down will end in 2036 with another 5% reduction.

What happens if you put R410 in R32 system?

Damage to system: Using the wrong refrigerant can cause your system to malfunction or even break down, which can significantly reduce its life span. Voiding warranties: Using a refrigerant other than the one intended by the manufacturer will automatically void your warranty in many cases.

Which is better, R32 or R-454B?

Comprehensive Environmental Impact Metrics

This means systems using R32 typically consume less energy over their lifetime, resulting in fewer indirect emissions. R454B, while also efficient, may require a larger charge size to achieve similar cooling performance, which can increase its overall environmental footprint.

Which gas can replace R-410A?

RS-53 (R470A) is a new non-flammable Drop-in replacement for R410A with a low Global Warming Potential (GWP) less than half that of R410A. RS-53 (R470A) has a similar thermodynamic performance to R410A with matching energy efficiency and cooling capacity.

What is the new freon coming out in 2025 in the USA?

What refrigerant will replace R-410A in 2025? For whole-home systems, Lennox has chosen 2025 Compliant Refrigerant R-454B due to its excellent performance for ducted systems and zero ozone depletion potential. For mini-splits, we selected R-32, designed to optimize efficiency and reliability in ductless systems.

Why is 410A so expensive right now?

Regulatory Changes: As the phase-out continues to restrict production levels and importation, the R-410A price will likely increase. Manufacturing Costs: Fluctuations in the cost of raw materials and manufacturing can also influence the price of refrigerants.

What happens if you put 410A in a R-22 system?

The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur.

Will R-410A be banned?

In December 2022, the EPA unveiled a refrigerant ban that will go into effect between 2025 and 2026 (depending on the industry). The result? R-410A is out, shaking up the HVACR industry, which relies heavily on this refrigerant.

Is R-454B available now?

R-454B has a lower GWP than previous refrigerants, meaning it has a much lower climate impact. Trane is phasing in the transition to R-454B in 2024, starting with the adoption of R-454B refrigerant in its residential products, beginning with the XR15 SEER2 heat pump.

What is the better refrigerant than R-410A?

In most cases, R32 is the superior refrigerant when compared to R410A. While neither refrigerant depletes the ozone layer, R32 has a lower GWP and is easier to recycle. R32 also has lower operating and maintenance costs and is nowadays more common than R410A due to the phase-out.

What is the drop-in replacement for 410A?

ComStar's RS-53 (R470A) is the world's only drop-in retrofit replacement for existing R410a systems. At 909, RS-53 has a GWP that is effectively 56% lower than R410a. Additionally, RS-51 (R470B) has a GWP of 717 which is 80% lower than R404a, R507 and half of R448A and R449A.

What HVAC manufacturers are going to use R32?

LG leads the way with R32 refrigerant

Now builders can take advantage of the many benefits of R32 refrigerant for their homeowners with LG solutions and technologies as a refrigerant that reliably keeps homes warm and cool.

Can R32 catch fire?

R32 has a flammable range of around 15 points so it meets the definition of the GHS for a Category 2.1 gas. Ammonia has similar flammability characteristics to R32 and is also a Class 2L refrigerant.

Can I convert an existing R410A system to R32?

Is it possible to upgrade the refrigerant in an existing unit? Please note that it is not possible to transition an R410A refrigerant unit to an R32 unit. Refrigerants should only be handled by trained, qualified technicians. These experts can assist you in finding an R32-capable system.

What are the disadvantages of R32 refrigerant?

Disadvantages:Different from R22 and R410A, the R32 is slightly flammable. But combustion will not occur unless three critical conditions are met, refrigerant concentration, constant oxygen, and an ignition source. In real practice, it's hard to meet all the combustion conditions.

Do you need a special vacuum pump for R32?

You will, of course, need to ensure that any equipment you use includes an R32 compliant recovery unit, an R32 specific vacuum pump, a torque wrench set to the manufacturer's recommendations on your flare joints and for pipework, stick to material that is R410A rated, as this also suitable for R32.

What new refrigerant will replace 410A?

What are my options for replacing R-410A? Because there are no retrofits for R410A, a replacement is needed. The replacements for R-410A are the two A2Ls, Forane® R-32 and R-454B. Forane® R-32 can be used in new equipment designed specifically for mildly flammable refrigerants as a replacement for R-410A equipment.

What is the average price of R-410A?

R-410 refrigerant costs $60 per pound on average, but can range from $40 to $75. Keep in mind you cannot purchase R-410A refrigerant without an HVAC pro. R-410A refrigerant prices range from $40 to $75 per pound.

What is the new freon coming out in 2025?

Starting in 2025, the HVAC industry will shift toward using refrigerants with a lower GWP. Among the most discussed replacements are R-32 and R-454B. These refrigerants perform similarly to traditional refrigerants like R-410A but with a significantly lower environmental impact.

Previous article
How deep should grout be between tiles?
Next article
What raises the electric bill the most?