What is the rule 32 110?

Author: Clemmie Oberbrunner  |  Last update: Tuesday, April 14, 2026

Each device is installed according to rule 32-110 and the manufacturers' instructions. Smoke alarms must be installed on each floor level, including basements, 900 mm or more above or below an adjacent floor level. Each bedroom must be protected by a smoke alarm either in the bedroom or outside.

How close do smoke detectors need to be to bedrooms?

Place a smoke detector in every sleeping area. Ensure a smoke alarm is outside of every room, like in a hallway. If you have a level without a bedroom, install a detector in the living room, or near the stairway leading upstairs or downstairs.

What to do if neighbour's smoke alarm keeps going off?

If there is someone living there you can call in a wellness check and police may visit and break in to check on them and verify why the no one is shutting off the alarm. Contact police on the non-emergency number and explain you want to ask for a wellness check and they will put you through to the relevant officer.

Do smoke detectors need an AFCI breaker?

Smoke alarms connected to a 15A or 20A circuit of a dwelling unit must be AFCI protected if the smoke alarm is located in one of the areas specified In 210.12(B).

How far should a smoke detector be from the AC unit?

Never place them any closer than three feet from an air register that might re-circulate smoke. Don't place them near doorways or windows where drafts could impair the detector operation. Don't place them on an uninsulated exterior wall or ceiling. Temperature extremes can affect the batteries.

Smoke alarm rules in Scotland

How many feet does a smoke detector have to be away from a HVAC register?

17.7. 4, recommends that detectors not be located in the direct airflow or closer than 36 inches from air supply diffuser or return air opening. This recommendation is intended to prevent airflow from diluting smoke or delaying smoke reaching the detector, both of which can significantly delay detection.

What are the requirements for a smoke detector in HVAC?

Many building owners working through retrofit or new construction projects are familiar with International Mechanical Code (IMC) standards, which state that an HVAC smoke detector be installed on any air handling system with a capacity greater than 2,000 cubic feet per minute (CFM).

Do you use 14-3 wire for smoke detectors?

Either a 15-amp circuit (wired with a 14-gauge wire) or a 20-amp circuit (wired with a 12-gauge cable) is acceptable when powering smoke detectors.

When should you not use AFCI?

If circuits are installed in a space for use other than a dwelling unit, AFCI is not required (commercial and industrial spaces are not required to have AFCI protection).

Can smoke detectors be on a GFCI circuit?

of the CE Code (2018), Rule 32-110 will permit a smoke alarm(s)—or a smoke alarm that includes a carbon monoxide alarm—to be connected to a GFCI/AFCI-protected circuit provided it has a battery-powered secondary supply.

What chirps every 40 seconds?

Consistently chirping smoke alarms

Low Battery – The alarm will chirp every 30-40 seconds (every 60 seconds for some alarms) for a minimum of seven days. Replace the battery when this occurs, then test your alarm. Alarm Malfunction – The alarm will chirp between flashes of the Red LED.

Can I call the fire department if my smoke alarm keeps going off?

1. My smoke alarm is going off constantly, but I do not see any smoke or fire. What should I do? Call 911 and report what you know.

How do you stop Neighbours smoke entering my house?

How to Block Cigarette Smoke from Neighbors. Set up a box fan so it blows out the window, which can help cycle smoke out of your apartment. You can also try sealing the smoke away with solutions like caulk or tape, door sweeps or draft guards, weatherstripping, electrical socket plugs, and/or insulation padding.

Where not to put a smoke detector?

Avoid near fresh air vents, ceiling fans or very drafty areas (drafts can blow the smoke away from the detector/alarm). Avoid installing closer than 4 inches from the wall or corners. Avoid installing closer than 12 inches from fluorescent lights.

How many carbon monoxide detectors should be in a home?

If you are installing only one carbon monoxide detector, the Consumer Product Safety Commission (CPSC) recommends it be located near the sleeping area, where it can wake you if you are asleep. Additional detectors on every level and in every bedroom of a home provide extra protection against carbon monoxide poisoning.

What is the code for installing smoke detectors?

For many years NFPA 72, National Fire Alarm and Signaling Code, has required as a minimum that smoke alarms be installed inside every sleep room (even for existing homes) in addition to requiring them outside each sleeping area and on every level of the home. (Additional smoke alarms are required for larger homes.)

What two areas in a dwelling do not require AFCI protection?

The shorter list is areas not requiring AFCI protection: unfinished basement areas, attached or detached garages, outdoor lighting and receptacles, accessory buildings and bathrooms are not required to be fed via an AFCI protected circuit.

Do outlets in attic need to be GFCI?

So, if you have air-conditioning equipment present in your attic, it is required that there be a 125v receptacle within 20-feet of the equipment so that anybody servicing the equipment has a receptacle to energize their tools. If this receptacle is present, it needs GFCI protection.

Should kitchens have GFCI or AFCI?

Since water is an electric conductor, GFCIs are important in areas where water and electricity could meet, such as bathrooms, kitchens, laundry rooms, and garages. Arc fault circuit interrupters help prevent electric fires. Electricity can leak out of damaged or decaying wires and start a fire.

Should all smoke detectors be on the same circuit?

The same fuse or circuit breaker in the home powers all interconnected units. The total length of wire interconnecting the units should be less than 1000 feet (300 meters), and the maximum number of interconnected units on the same circuit is 18 total units, with 12 of those being smoke detectors.

Where does orange wire go on smoke detector?

Tuck the orange wire inside the junction box. It is used for interconnect only.

Are hardwired smoke detectors worth it?

If you want detectors you can depend on that don't run the risk of faulty batteries, then hard wiring them is the way to go. We do suggest having backup batteries in the case of a power outage, but a hardwired smoke or CO alarm will otherwise always be functional and will keep you and your family safe.

What is the code for duct smoke detectors?

NFPA 90A and International Mechanical Code

The International Mechanical Code requires a duct smoke detector in the return for units over 2000 cfm and requires a detector in the supply duct for systems over 15,000 cfm.

How many cfm per ton?

“The conditioned air quantity for air conditioning should be about 400 CFM per ton of cooling capacity.”

What is the only approved way to test a smoke detector?

There are five allowed methods.
  1. Calibrated test method.
  2. Manufacturer's calibrated sensitivity test instrument.
  3. Listed control equipment arranged for the purpose.
  4. Smoke detector control unit arrangement whereby the detector causes a signal at the control unit when its sensitivity is outside its listed sensitivity range.