An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting
R422D is quickly becoming a popular substitute for R22. R422D does not require changing out the oil! To learn more about R422D visit our landing page at http://stores.johnstonesupply.com/88/ and click on July's News "U" Can Use.
As a solution, there are two alternative refrigerants used as substitute refrigerant for R22, namely R290 and R32. The R290 is widely used as working fluid in A/C system of Europe countries; meanwhile in Japan and South East countries, R32 is utilized as substitute refrigerant for R22 and R410A (Yu et al., 2010).
410A compressors are totally incompatible with R22 they are mechanically designed different and have different oil the air handler can be used but the metering device, either piston or TXV needs to be changed out to one rated for 410A and system needs flushed and purged out new filter dryers and the works.
When you replace an air conditioner or heat pump and upgrade from R-22 to R-410A, the ideal solution is to replace your refrigerant lines. This is because the mineral oil used in R-22 systems is not compatible with the new R-410A refrigerant and oil.
Since R410A refrigerant is charged under higher pressure, charging an R22 system with it will increase the force within the coolant lines. The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur. Mixing refrigerants is not an option either.
How much will an R-22 to R-410A conversion cost? The actual cost will depend on many things, including where you live, but most of the time R-22 conversions start at around $2,000 and go up from there. The higher end of that range is somewhere around $4,500 to $4,600.
Since 2010, the most common R-22 replacement was R-410A, a refrigerant without the ozone-depleting qualities of R-22. Read this article on the refrigerant transition for a more thorough explanation of the reasoning and science behind the change.
To retrofit an R-22 system with R-410A system your line set must not be more than 25-50 feet in total distance. If the line set is longer than this, you will have to replace the line set with larger lines.
Yes. The mass flow rate and operating pressures of Freon™ MO99 are the closest of all the mineral oil compatible replacement products and will likely perform adequately in an existing R-22 system with a capillary tube expansion device.
Changes to the Dangerous Goods Legislation, effective in 2021, has new categories for A2L refrigerants. R32 is a synthetic greenhouse gas. If released to the atmosphere it can contribute to climate change. R32 is a flammable refrigerant.
With the R22 phase out in 2020 due to its environmental impact, this is a common question for those looking to upgrade their system or change the refrigerant in their system. The answer is no, refrigerants should not be mixed.
What refrigerant will replace R-410A in 2025? For whole-home systems, Lennox has chosen 2025 Compliant Refrigerant R-454B due to its excellent performance for ducted systems and zero ozone depletion potential. For mini-splits, we selected R-32, designed to optimize efficiency and reliability in ductless systems.
Using these retrofit guidelines, many R-22 systems can be retrofitted for use with Freon™ 407C in air conditioning, heat pump applications, and refrigeration applications to allow existing equipment to continue to operate safely and efficiently, even after R-22 is no longer available.
No, the compressor will fail. These two refrigerants have very different properties. One of R22 and R134a is high pressure and the other is low pressure. They don't mix chemically and don't have the same boiling point, leading to inefficiencies and eventual compressor failure.
Freon MO99 is the closest capacity match to R-22, compared with most other no-oil change refrigerants.
R32 has a higher compressor discharge temperature than R410A, and will increase wear on the compressor, reducing its life significantly. Should any problem arise from a system change such as this, any liability would rest ENTIRELY with the person who carried out the change.
You cannot just switch refrigerants because R410-A and R-22 have different chemical properties. R410-A operates at a higher pressure. If you put R410-A into an R-22 system, the parts will rupture due to the increased force.
The industry-wide phaseout of R-22 to meet mandates to reduce high ozone-depleting potential (ODP) refrigerants depends on alternative options such as Freon™ MO29. This nonflammable HFC alternative offers a host of benefits that include: Cost-effective retrofits (and easier retrofitting) than R-404A, R-507, and R-407C.
The best replacement for R-22 Freon is usually R-407c. It has a very low loss in capacity (0 – 5%) relative to R-22 and is less expensive than many other R-22 replacement refrigerants. If a system has R22 in it already you cannot use a replacement refrigerant to simply add to the R22.
As Freon was phased out, new HVAC systems began using a refrigerant known as Puron® or R-410A, an HFC. More efficient and less harmful to the environment, R-410A has been in use since its introduction in 1996 and is found in most of today's modern HVAC systems.
Compatibility: R32 is compatible with existing air conditioning systems that use R22 and R410A, making it a suitable alternative for retrofitting existing systems. However, it's important to consider compatibility with the specific system and components before retrofitting to R32.
Why is R-22 refrigerant so expensive? R-22 refrigerant is so expensive because there's such a limited supply of it left. You see, R-22 is an “ozone-depleting substance” and is extremely harmful to the environment.
Of all the "no oil change" replacement refrigerants, Freon™ MO99™ offers the closest performance match to R-22.