What freon can be mixed with R22?

Author: Isai Denesik  |  Last update: Monday, November 17, 2025

So… what refrigerant can be mixed with R-22? None. You can't mix refrigerants.

What refrigerant can top off R-22?

Freon™ MO99 can be used to retrofit R-22 heat pumps . Based on system testing, similar efficiency and slightly lower capacity can be expected.

What freon is compatible with R-22?

Freon MO99 is the closest capacity match to R-22 compared with most other no-oil change refrigerants.

Can you mix R-22 with other freon?

No, Mixing R22 with R407C or any other refrigerant. According to the 609 EPA rule, mixing refrigerants is illegal and anybody caught doing so will be heavily fined. If your system is running on R22 most likely is using mineral oil to lubricate the compressor.

What happens if you mix R-22 and 407C?

Comments Section
  • mixing refrigerants is illegal.
  • 407c cant run with mineral oil like r-22 can, so if that's what's in your system it will eventually kill it.

Best replacement for r22 refrigerant gas in refrigeration and air-conditioning

What gas can you mix with R-22?

So… what refrigerant can be mixed with R-22? None. You can't mix refrigerants.

Can you mix 404a and R-22?

No ,R404A works at higher pressure and is much better in absorbing and releasing heat .

What is a drop-in substitute for R-22?

R-421A is a drop-in replacement for R22 systems. With this refrigerant there is no need to change the oil. Simply recover the R22 and recharge with R421A. Experiencing R421a problems? Read this guide.

Can you put 410A Freon in a R-22 system?

As you might imagine, this isn't going to go well for your air conditioner or heat pump. Long story short? Never mix R-22 and R-410a. Unless of course you are looking to destroy your HVAC system, then, by all means, go live that dream.

Can I put R134a in a R-22 system?

No, the compressor will fail. These two refrigerants have very different properties. One of R22 and R134a is high pressure and the other is low pressure. They don't mix chemically and don't have the same boiling point, leading to inefficiencies and eventual compressor failure.

How much does it cost to convert R-22 to R410A?

How much will an R-22 to R-410A conversion cost? The actual cost will depend on many things, including where you live, but most of the time R-22 conversions start at around $2,000 and go up from there. The higher end of that range is somewhere around $4,500 to $4,600.

Can you mix R-22 and rs 44?

The Environmental Protection Agency (EPA) in the United States does not permit the mixing of different refrigerants. However, it is known from experience in Europe that the unintended mixing of RS-44b with R22 will not generate higher pressure readings, loss of efficiency or component damage.

Can R-22 still be purchased?

In 2010, the U.S. stopped the sale of newly manufactured residential air conditioning units and heat pumps that use R-22 because of its particularly harmful impact on the ozone layer when released into the air. On January 1, 2020, the U.S. Environmental Protection Agency (EPA) banned the production and import of R-22.

What Freon is compatible with R22?

An R-22 Refrigerant Replacement for Direct Expansion Refrigeration. Freon™ MO29 (R-422D) refrigerant is a low-toxicity, non-ozone depleting hydrofluorocarbon (HFC) replacement for R-22.

Can I mix MO99 with R22?

Mixing refrigerants is not recommended.

Can I recharge R22 myself?

As of Jan 1 2020, R22 refrigerant has been completely phased out worldwide due to its harmful effects on the ozone layer. It is no longer being produced. If you're interested in learning how to refill R22 in your air conditioner, it is important to know that this is not something a homeowner can do on their own.

What happens if you accidentally put 410A in a R-22 system?

Since R410A refrigerant is charged under higher pressure, charging an R22 system with it will increase the force within the coolant lines. The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur. Mixing refrigerants is not an option either.

What can I use instead of R-22 refrigerant?

R410A is the most common, but others include R134a, R407C and R407A. These refrigerants cool interior spaces just as effectively as R22 with no ozone depleting characteristics and relatively low Global Warming Potential (GWP).

Can you mix freon with R-22?

With the R22 phase out in 2020 due to its environmental impact, this is a common question for those looking to upgrade their system or change the refrigerant in their system. The answer is no, refrigerants should not be mixed.

Can you put 407C in a R-22 system?

R-407C should be used only in systems that currently use R-22. It should not be mixed with R-22 or any other refrigerant. 5. The capacity of the existing R-22 thermal expansion valve (TEV) will be approximately the same when using R-407C.

Why was R-22 phased out?

Because R-22 depletes the ozone layer, production and import was further limited in 2010. In 2020, R-22 will no longer be produced or imported. After 2020, only recovered, recycled, or reclaimed supplies of R-22 will be available.

What gas can replace R-22 refrigerant?

R417A refrigerant is an HFC mixture that serves as a substitute for R22. It is compatible with traditional lubricants. In most cases, the lubricant type does not need to be changed in the event of retrofitting.

Is 404A a drop-in for R-22?

The biggest problem of using refrigerant R404A to replace refrigerant R22 is the problem of lubricating oil. PVE ester oil must be used to replace the mineral lubricating oil for R22. Ester lubricants have high affinity with water and poor dehydration.

Which refrigerant can be mixed?

Can I Mix Refrigerants? Unlike many HVAC-related questions, the answer to this is an unequivocal no. This is true even if a product is advertised as mixable or even if a technician tells you it's OK to mix! Different refrigerants use different oils to lubricate the system, and these oils don't mix.

Can you use the same line set from R-22 to 410A?

To retrofit an R-22 system with R-410A system your line set must not be more than 25-50 feet in total distance. If the line set is longer than this, you will have to replace the line set with larger lines.

Previous article
How can I make my thermostat more accurate?
Next article
How do you make homemade power washer solution?