HVAC maintenance companies explain that a furnace will normally perform an average of two to three cycles in an hour, with each cycle lasting 10 to 15 minutes. But to keep temperatures at a comfortable level during cold weather, a furnace might need to increase this range to three to 10 cycles.
With an effective air delivery system and a well-insulated home, this should be long enough to establish your preferred temperature throughout the building. After resting for approximately five to 10 minutes, your furnace will likely cycle on again.
If your furnace keeps turning off and on, your thermostat may be the culprit. A malfunctioning or improperly placed thermostat can cause your furnace to short cycle. Common issues include: Old wiring or dead batteries: Replace batteries or old wiring to ensure accurate temperature readings.
Most furnaces kick on and off between three to eight times an hour, depending on things like outdoor air temperatures, the furnace's age, and how much insulation you have. That's why, instead of asking how often a furnace should cycle, it's best to stay alert to changes in how your furnace is running.
One possible issue for a furnace running only for 5 minutes could be a malfunction with the thermostat. The thermostat is responsible for regulating the temperature in your home and communicating with your furnace to turn on and off as needed.
Blocked vents or a clogged air filter may cause your furnace to run and then shut off too early. It's easy to fix these issues on your own. You should change your furnace filter at least once every three months. Follow our guide to do it yourself.
A furnace “short cycles” when it turns off before reaching the desired temperature. This means that if your thermostat is set to 72 degrees, the furnace may shut down at 65 or 68 degrees, but will never reach 72 degrees. Short cycling can also be used to describe a furnace that turns on and off too often.
But in general, your furnace should not constantly be running. Otherwise, it could indicate a problem with your heating system. In this case, have a qualified HVAC (Heat, Ventilation, and Air Conditioning) technician inspect your system and address issues that make it run constantly.
Having a dirty air filter in your furnace can cause short cycling. While a faulty flame sensor will lead to an immediate shut-off, a dirty filter will allow your furnace to run for several minutes and then shut down. You might notice that the air being pumped out of the heat grates is significantly hotter than normal.
So how fast should a furnace heat a house? On average, once you turn on your furnace, it should take about an hour to increase indoor temperature by 1 degree. Afterwards, it's 45 minutes per degree.
A furnace cycling on and off repeatedly can be caused by various reasons, from dirty filters and obstructions in ducts and registers to incorrect thermostat settings and faulty limit switches. By following the steps above, you can help prevent your furnace from cycling too frequently and save energy costs.
Dirty Air Filters
So, the furnace is triggered to stop, then it cools down only to fire back up again. This short cycling continues to repeat until the furnace receives the airflow it needs. Dirty air filters are one of the most common reasons behind furnace short cycling.
If someone is at home in the daytime, 72° F (22° C) is a good start, but aim for 68° F (20° C). If everyone is away from home in the daytime or you're asleep at night, we feel 66° F (19° C) to 62° F (17° C) is best.
While it should cycle throughout the day, clicking on too frequently may indicate a problem. Homeowners often find themselves wondering, "How often should my furnace cycle?" The answer lies in a gray area. On average, furnaces should kick on and turn off anywhere from three to eight times per hour.
Typically, a furnace should cycle three to eight times per hour. While furnace cycling is normal, frequent cycling can indicate that your heating is struggling to keep up. We've put together this guide to help you understand the difference between normal furnace cycling and short cycling.
Leave the breaker(s) off for at least 10 minutes while the system is off and “rebooting.” After 10 minutes have elapsed, go back to the breaker box and flip the HVAC breaker(s) back on.
With all that being said, if there are no extreme factors involved, the average run time for a furnace is 10-15 minutes per cycle. Your furnace may need to run two to three times an hour to maintain your desired temperature if your home has average insulation.
Ask twenty professional HVAC contractors the question, “How Much Does A New Furnace Cost?” and you'll probably get the same answer... “It depends.” On average, the cost of a new furnace can range from $2,000 - $14,2001. However, factors like furnace efficiency, type, size, and much more can impact this range.
The simple solution: Turn your furnace off and check the filter. If it's dirty or it's been 3 months or more since you changed it, put a new, high-quality filter in place.
The Average Furnace Lifespan
A well-maintained furnace can last at least 15 to 20 years, but completing annual maintenance and being diligent with repairs can extend its life even longer.
If your furnace turns on, and off, and back on again in a seemingly endless loop, you're experiencing short cycling. Essentially, short cycling occurs when the system cannot complete a full heating cycle. There's no one cause of short cycling, but with some troubleshooting you can get to the bottom of the issue.
A high-efficiency furnace should be running at least 80% of the day if not longer.
Routine Furnace Cycles and How Often the Heater Runs
So is running as long as 20 minutes. Even running every seven or eight minutes may not be a problem, as other factors could lead to more frequent cycling. Outside temperature, for example, could contribute to how fast or slow the furnace cycles.
This means the compressor will run for 10 minutes, stop for 10 minutes, and repeat the cycle two more times during a single hour. You can tell a system that's short cycling when it turns on and off three times in five to ten minutes.