Some commonly occurring signs that you have a problem with your blower fan are that there is no air coming out of the registers even though the system is running, there is a loud rattling noise, and there is a burning-type smell within the system.
A faulty AC fan motor can overload the electrical circuit, leading to frequent tripped circuit breakers. This occurs when the motor draws excessive electrical current due to a malfunction or damage. Professional inspection and repair can prevent further electrical issues and ensure your AC is operating safely.
Unusual and Loud Sounds
A failing blower motor may emit unusual sounds. This may sound like screeching or squealing if it has bad bearings. You may hear a rattle or a banging sound if something inside the motor has broken or come loose.
Generally, when power vent motors burn out early it is caused by a lack of intake ventilation. If there is not enough intake for the CFM rating of the power vent (CFM = cubic feet of air moved per minute), the fan will be working harder than it should.
You will hear the capacitor clicking every few seconds if it is bad. This noise is the capacitor trying to release the energy needed for the unit's motors to start. If the start capacitor fails, you will typically hear the motor make a loud humming noise.
If your blower motor is experiencing some issues, you may hear a high-pitched squeal or whistling sound. You may also experience rattling and loud screeching noises. The motor blower pushes warm air out of the furnace through the ducts into your home.
Signs of Trouble: Watch out for wobbling blades, unusual noises, or sluggish fan speeds. These could indicate worn-out parts, loose connections, or a failing motor, all signs it might be time for a replacement.
What's the Cost of Repairing or Replacing a Fan Motor? The average cost of a condenser fan motor is between $300 and $500 (not including installation). If the compressor breaks, you are looking at a much costlier problem which could cost up to $2000. In some cases, your fan motor may be under warranty.
A blower motor should last at least 10 years, and could last up to 20, depending on the type of HVAC unit you have in your home. There are a few warning signs that your blower motor is damaged, including little-to-no airflow coming from your vents, a burning smell, and skyrocketing energy bills.
You can also troubleshoot a fan motor by testing the windings with an ohm meter. A 120V fan motor has black, blue, red, and yellow wires, plus a white wire, black wire, and two brown wires. Check the resistance between the white wire and each colored wire. If it reads zero, the motor winding may have a short.
Your AC is rendered useless without a functioning fan or furnace blower motor. This could also mean that you need a furnace repair or should start looking at costs for blower motor replacement. In addition, you will either suffer from no air or weak airflow with fan problems.
The motor won't spin – If the rotor that holds the fan blower wheel won't spin or is hard to spin, it's a good sign that the blower motor is shot. Once again, if the motor is getting proper voltage and the capacitor is good, but the blower won't freely spin, it may have seized, which is not uncommon.
If the blower motor is going bad, it will struggle to operate the fan. The result will be weak airflow coming from the vents inside your living spaces. This airflow issue can be one of the main symptoms that indicate the component needs to be replaced.
Electrical Burning Odor
Electrical burning smells can be highly alarming. This odor could indicate an overheated blower motor. Blower motors commonly overheat due to clogged air filters.
Weak Airflow from the Vents
This is usually the first indication that you may have a faulty blower motor. If the airflow coming out of the vents is weak, check the motor. It can mean that your furnace blower motor is having a hard time pushing enough air through the ducts to achieve your desired temperature.
On some platforms, a faulty blower motor relay will cause the blower not to work at all, which means there will be no airflow from the A/C. On others, the blower won't work on “high blow” but all the other speeds will work. The blower motor relay fails because it regularly deals with high current loads.
Will AC fans run if the capacitor is bad? The answer is a resounding no. An air conditioning unit will stop working with a faulty capacitor unless you get hold of Coral Springs' air conditioning repair experts.