Can an air admittance valve replace a vent?

Author: Miss Gracie Wolff Jr.  |  Last update: Thursday, May 28, 2026

Air Admittance Valves (AAV) — Oatey ®Sure-Vents® — are mechanical devices installed to a plumbing fixture, replacing a secondary vent. These valves allow one-way ventilation, removing the need to connect to an existing venting system or run a separate, potentially unsightly ventilation system.

What is the downside to an air admittance valve?

The main problem with using an Air Admittance Valve instead of a Soil Vent Pipe, as discussed earlier, is that by preventing the gases from escaping through the top of the soil stack you are causing them to be forced down into the main drains and sewer system instead.

What is the alternative to a vent pipe?

To save money. For these reasons, using an AAV requires less labor and supplies, making it a more affordable option than running vent pipe in new construction applications.

Where are air admittance valves not allowed?

Air admittance valves are not permitted in spaces where pressure conditions adversely affect the valve's operation. They are also not allowed in concealed wall and ceiling spaces used as plenums as part of an air distribution system that is under negative or positive pressure.

Why is Studor vent illegal?

The Studor vent lets that air to be sucked in the pipe during water flow but doesn't let sewer gas escape out. Code is the thing that determines pipe size and also water flow. Hence no studor vents are permitted to toilets because more air is required to keep water flow going with more waste added to the toilet.

Air admittance valves for plumbing venting explained, [just over 4 minutes]

Does an air admittance valve replace a vent?

Air Admittance Valves (AAV) — Oatey ®Sure-Vents® — are mechanical devices installed to a plumbing fixture, replacing a secondary vent. These valves allow one-way ventilation, removing the need to connect to an existing venting system or run a separate, potentially unsightly ventilation system.

What are the rules for air admittance valves?

The short answer is a minimum of 200mm above any water entry point. So if you imagine your soil pipe run, then durgo valve / AAV must be fitted above the highest connection to the soil pipe from any sink, bath or toilet that is connected to it.

What is the life expectancy of an air admittance valve?

Air admittance valves have a typical life expectancy of 20-30 years, so if you start to have issues with sewer gases or smells being released around your sink or in the attic-wherever installed- the air admittance valve could be faulty or failed and should be replaced as soon as possible.

Are cheater vents legal?

Sometimes called "cheaters," these tubular, spring-loaded $5 vents are rated for only 1/2 DFU (drainage fixture unit), and are not allowed under most building codes.

What are the requirements for a studor vent?

When a Studor® valve is installed in an attic, it must be installed a minimum of 6” above insulation. The Studor valve must be installed a minimum of 4" above the horizontal branch the horizontal branch drain or fixture drain being vented. Studor AAVs must be installed within 15 degrees of the vertical position.

Can you replace a vent?

New vent: Depending on the type of vent you have, you may need to purchase a replacement vent. It's vital to choose a vent that is the same size and type as the old one to guarantee a proper fit.

Can an air admittance valve be used to vent a toilet?

Yes, an air admittance valve can be used to vent a toilet. This valve is a device designed to allow air to enter the plumbing drainage system to balance the pressure, keeping water from getting pulled out from traps in the plumbing fixtures.

How do you vent a kitchen without a vent?

Use a Window Fan

Using a window fan in the kitchen can bring some great advantages. Firstly, it helps with ventilation by creating a flow of fresh air. When you're cooking, steam, smoke, and lingering odors can fill the air.

Where is the best place to put an air admittance valve?

AAV location

An AAV should be located within the maximum developed length permitted for the vent. It must be located a minimum of 4” above the horizontal branch drain, 6” above any insulation material and within 15 degrees of vertical.

How long does an AAV last?

How long does an AAV last? Adeno-associated viruses (AAVs) are stable for several months to years when stored properly at -80°C.

Do AAV vents smell?

Yes. Any AAV can malfunction or not operate properly because it is a mechanical device. Signs of that the Sure-Vent is not operating as intended, are foul odors.

What is the difference between an air admittance valve and a cheater vent?

Automatic air vents are spring type devices often referred to as in-line or cheater vents, while air admittance valves have no spring. Air admittance valves are more expensive and are approved in many jurisdictions where in-line and cheater vents are not because of their moving parts (springs).

Does the AAV go before or after the trap?

Air admittance valves are typically placed between the P-trap of a fixture and the drain line. They're usually mounted on one leg of a sanitary tee, with the other leg going to the drain. The unit must be placed per local codes and the manufacturer's instructions.

Can a studor vent go bad?

They are however overused so if you can put a traditional vent in it is best to do because the studor vent does not last forever and they do go bad and need replacement from time to time.

What is the problem with the air admittance valve?

Potential issues with air admittance valves

Sometimes unwanted smells may be emitted, gargling sounds may occur or wastewater comes up from the soil pipes into the sink. All of which are signs that there may be an issue with the air admittance valve. Occasionally the valve may get stuck.

How do I know if my AAV vent is failing?

An air admittance valve leaving behind clogs and sewer odor is faulty, so be sure to find your receipt if you still have it and take the valve back as soon as you see that it is not working.

What height should an air admittance valve be installed?

External Air Admittance Valves will allow the installation of an external soil pipe within 3 metres of any opening and terminate at the same height as if it were installed internally, i.e. 200mm (minimum) above the highest wet entry point to the soil vent pipe.

In what states are air admittance valves legal?

They are not illegal in California as a state because California Plumbing Code allows "Engineered Vent Systems" see Section 911.0.

Are air admittance valves a good idea?

An AAV can significantly reduce the number of venting materials needed in a plumbing system. That's money in the pocket of the plumber. They also allow greater flexibility in the layout of plumbing fixtures and reduce long-term roof maintenance. If we don't have a hole in the roof, it's easier to maintain it.

Are air admittance valves to code?

Individual and branch-type air admittance valves shall conform to ASSE 1051. Stack-type air admittance valves shall conform to ASSE 1050. The valves shall be installed in accordance with the requirements of this section and the manufacturer's instructions.