Why is my furnace running every 10 minutes?

Author: Randi Grady I  |  Last update: Wednesday, February 19, 2025

Losing too much heat through the roof, windows, or doorways will cause your furnace to run more often. High ceilings and single-pane windows are common culprits. If your furnace only turns on for a few minutes at a time, but your home never warms up, it's probably short cycling.

Is it normal for my furnace to run every 10 minutes?

Furnaces typically run for about 10 to 15 minutes in moderate weather. Extreme cold can result in longer cycle times. Positive and negative factors that can affect furnace run time include: Sizing: A furnace correctly sized for heating the area operates more efficiently.

Why does my heat run for 10 minutes then shuts off?

Common causes of furnace short cycling include restricted airflow, a malfunctioning flame sensor, or a poorly placed thermostat.

Is it normal for a furnace to kick on every 5 minutes?

If the time between cycles is less than five minutes, the furnace is most likely short-cycling. Heating cycles that run for shorter periods of time produce more frequent heating cycles. Depending on the outside temperature and how well-insulated your home is, these short cycles may occur five to eight times per hour.

Is it normal for a furnace to turn on every 10 minutes in winter?

During an average heating cycle, a furnace should operate for 10-15 minutes. If you're wondering how often furnaces cycle, the answer is: it depends. Furnaces in homes with average insulation might run two to three cycles per hour to heat the living space properly.

3 Reasons Your Furnace Cycles On and Off Frequently

Why is my furnace turning off every 15 minutes?

The most common reason for short cycling is that the air filter is dirty and, therefore, non-functional. This is because the heat exchanger can retain heat to such an extent that it overheats. On the bright side, you will not have to look up “HVAC repair near me” as you can replace the filter on your own.

How long should my furnace stay off between cycles?

With an effective air delivery system and a well-insulated home, this should be long enough to establish your preferred temperature throughout the building. After resting for approximately five to 10 minutes, your furnace will likely cycle on again.

Why does my furnace run for 5 minutes then shut off?

Having a dirty air filter in your furnace can cause short cycling. While a faulty flame sensor will lead to an immediate shut-off, a dirty filter will allow your furnace to run for several minutes and then shut down. You might notice that the air being pumped out of the heat grates is significantly hotter than normal.

How to tell if furnace is short cycling?

If your furnace turns on, and off, and back on again in a seemingly endless loop, you're experiencing short cycling. Essentially, short cycling occurs when the system cannot complete a full heating cycle. There's no one cause of short cycling, but with some troubleshooting you can get to the bottom of the issue.

Why does my furnace go on and off too frequently?

One of the most common causes of a furnace shutting off unexpectedly is low airflow. If your furnace keeps turning off, check for issues such as: Dirty Air Filters. A clogged filter restricts airflow, causing the furnace to overheat.

Why does my heat come on every 20 minutes?

A dirty air filter is the most common cause of short-cycling. If the air filter is clogged with dirt, it won't allow proper air flow to the heat exchanger.

Why does my furnace run for 30 minutes then shut off?

The most common problems that cause a furnace to short cycle include: An overheating heat exchanger. A dirty flame sensor rod. A blocked flue pipe.

How do you know if you have a bad flame sensor?

Short cycling is a common sign of a bad flame sensor. The sensor thinks that there isn't a flame, so it shuts off the gas as a safety mechanism. Except, there is a flame and without the gas to supply it, it dies. This is a frustrating problem, but an HVAC technician can fix it.

How many minutes should a furnace run per cycle?

HVAC maintenance companies explain that a furnace will normally perform an average of two to three cycles in an hour, with each cycle lasting 10 to 15 minutes. But to keep temperatures at a comfortable level during cold weather, a furnace might need to increase this range to three to 10 cycles.

How to stop a furnace from short cycling?

Solutions:
  1. Cleaning the Flame Sensor: ...
  2. Replacing a Faulty Sensor: If cleaning doesn't resolve the issue or the sensor is damaged, replace it with a new one.
  3. Regular Maintenance: Schedule annual furnace maintenance to ensure all components, including the flame sensor, are in good working condition.

What temperature to set thermostat in winter?

If someone is at home in the daytime, 72° F (22° C) is a good start, but aim for 68° F (20° C). If everyone is away from home in the daytime or you're asleep at night, we feel 66° F (19° C) to 62° F (17° C) is best.

Is it normal for a furnace to run every 10 minutes?

Industry research shows some expected time frames for how long a furnace runs during a particular cycle. Running 10 to 15 minutes per cycle seems acceptable. So is running as long as 20 minutes. Even running every seven or eight minutes may not be a problem, as other factors could lead to more frequent cycling.

Why does my furnace only run for 15 minutes?

3- Furnace Shuts Off After 15 Minutes Due to a Dirty Air Filter. If your furnace shuts off after 15 minutes, a dirty air filter is likely blocking your heat.

Why does my furnace shut off after 10 minutes?

If your furnace shuts down after a few minutes, it's likely due to a faulty or unhygienic flame sensor. This crucial component intends to monitor the gas burner. Also, when a flame sensor cannot detect the burner, the furnace runs for a few moments before shutting down and restarting.

Is short cycling bad for a furnace?

When a furnace is short cycling, it's working hard to produce heat but isn't making any, causing strain on your furnace. If left unchecked, this could cause major issues for your furnace resulting in hefty repairs.

Is it normal for furnace to kick on every 20 minutes?

While it should cycle throughout the day, clicking on too frequently may indicate a problem. Homeowners often find themselves wondering, "How often should my furnace cycle?" The answer lies in a gray area. On average, furnaces should kick on and turn off anywhere from three to eight times per hour.

Why is my furnace coming on every 5 minutes?

A furnace cycling on and off repeatedly can be caused by various reasons, from dirty filters and obstructions in ducts and registers to incorrect thermostat settings and faulty limit switches. By following the steps above, you can help prevent your furnace from cycling too frequently and save energy costs.

Can a bad thermostat cause a furnace to run continuously?

If your thermostat is not working properly, it may not be able to accurately read the temperature in your home or properly communicate with your furnace. This can cause your furnace to run continuously, even if your home is already at the desired temperature.