There are multiple reasons why your furnace is short cycling. These could include a dirty filter, blocked vent, or malfunctioning flame sensor. You can switch for a clean furnace filter, or have your HVAC technician resolve a more complicated issue.
Having a dirty air filter in your furnace can cause short cycling. While a faulty flame sensor will lead to an immediate shut-off, a dirty filter will allow your furnace to run for several minutes and then shut down. You might notice that the air being pumped out of the heat grates is significantly hotter than normal.
The simple solution: Turn your furnace off and check the filter. If it's dirty or it's been 3 months or more since you changed it, put a new, high-quality filter in place.
Furnaces need cold air for the heat exchanger to heat up. If there isn't enough coming in, the system will shut itself off as a safety measure. Once the internal temperature within your furnace stabilizes, it will kick back on again. However, the dirty air filter forces the furnace to repeat this short cycling.
Insufficient airflow or insufficient gas pressure. A defective, malfunctioning ignition board, flame sensor, light switch, thermostat, thermocouple, fan limiter, or draft inducer fan. The drainage line is blocked, resulting in a full condensate pan. Temperatures are so low that the furnace cannot stay lit.
You've left the same air filter in place for too long
Dirty air filters are perhaps the most common reason that furnaces fail to provide enough heat to a home. (They're behind plenty of other problems as well.) Over time, this air filter will become clogged with dust, dirt, and other debris.
A bad thermostat can be detected when your AC or furnace is not turning on, your HVAC systems are not turning off, the thermostat not responding, your HVAC system is short-cycling, the room temperature not matching the temperature displayed on the thermostat, and the programmed setting resetting themselves.
Gas Supply Issues: Problems with the gas supply, such as low pressure or blockages in the line, can prevent the gas from reaching the pilot light. This can result in the pilot light failing to ignite or going out unexpectedly. Drafts or Airflow Problems: Sometimes, drafts near the furnace can blow out the pilot light.
Common issues include: Old wiring or dead batteries: Replace batteries or old wiring to ensure accurate temperature readings. Thermostat location: If your thermostat is too close to a heat source (like sunlight or a heat register), it can misread the temperature and cause your furnace to keep shutting off.
Oversized furnace
This is the most common cause of furnace short cycling. If the furnace has been short-cycling since it was first installed, it may have been improperly sized for your home.
When a furnace is short cycling, it's working hard to produce heat but isn't making any, causing strain on your furnace. If left unchecked, this could cause major issues for your furnace resulting in hefty repairs.
Poor Airflow
Inspect vents and grates to ensure they're open and unobstructed. Blocked vents can prevent proper circulation, leading to overheating and automatic shutdown of the furnace. By keeping vents clear and ensuring adequate airflow, you can help ensure your system operates reliably through long winter nights.
Ask twenty professional HVAC contractors the question, “How Much Does A New Furnace Cost?” and you'll probably get the same answer... “It depends.” On average, the cost of a new furnace can range from $2,000 - $14,2001. However, factors like furnace efficiency, type, size, and much more can impact this range.
There are multiple reasons why your furnace is short cycling. These could include a dirty filter, blocked vent, or malfunctioning flame sensor. You can switch for a clean furnace filter, or have your HVAC technician resolve a more complicated issue.
There is a work-around to waiting. If there is no safety risk (like a gas leak), a furnace can be reset to bypass this wait. Turn off the furnace's power switch and wait 10 seconds before turning it back on.
So, when the flame sensor doesn't sense a flame, the unit's pilot light remains unlit, and the gas valve closes.
While the average life span of a flame sensor is about five years, many technicians recommend replacing the flame sensor a little more often at every two to three years. This schedule helps ensure that the flame sensor is always in good condition and not causing problems with the gas supply.
If your furnace is not producing heat, there are several potential causes. These include but are not limited to a broken thermostat, the thermostat being set too low, an extinguished pilot light, a blown fuse or tripped circuit breaker, a closed gas valve, or issues with the electronic ignition.
Short cycling indicates a problem within a heater that is cutting off its heating cycle before it finishes. This can be caused by a range of issues, which vary in severity and necessary repair.
Turn on the heat on the thermostat and increase the temperature. You should hear a sound from both the thermostat and the furnace, and whichever doesn't make a sound has a problem.