Where are air admittance valves not allowed?

Author: Dr. Gus Cole Jr.  |  Last update: Saturday, February 14, 2026

Air admittance valves are not permitted in spaces where pressure conditions adversely affect the valve's operation. They are also not allowed in concealed wall and ceiling spaces used as plenums as part of an air distribution system that is under negative or positive pressure.

What are the restrictions for air admittance valves?

Individual and branch-type air admittance valves shall vent only fixtures that are on the same floor level and connect to a horizontal branch drain. Individual and branch air admittance valves shall be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented.

Why is studor vent illegal?

The Studor vent lets that air to be sucked in the pipe during water flow but doesn't let sewer gas escape out. Code is the thing that determines pipe size and also water flow. Hence no studor vents are permitted to toilets because more air is required to keep water flow going with more waste added to the toilet.

In what states are air admittance valves legal?

They are not illegal in California as a state because California Plumbing Code allows "Engineered Vent Systems" see Section 911.0.

What is the downside to an air admittance valve?

The main problem with using an Air Admittance Valve instead of a Soil Vent Pipe, as discussed earlier, is that by preventing the gases from escaping through the top of the soil stack you are causing them to be forced down into the main drains and sewer system instead.

Air admittance valves for plumbing venting explained, [just over 4 minutes]

What is the life expectancy of an air admittance valve?

Air admittance valves have a typical life expectancy of 20-30 years, so if you start to have issues with sewer gases or smells being released around your sink or in the attic-wherever installed- the air admittance valve could be faulty or failed and should be replaced as soon as possible.

Does an air admittance valve stop smells?

Air admittance valves often feature rubber seals, to help create a complete seal, increasing the effectiveness of the valve and preventing any odours from escaping through small gaps.

Where is the best place to put an air admittance valve?

AAV location

An AAV should be located within the maximum developed length permitted for the vent. It must be located a minimum of 4” above the horizontal branch drain, 6” above any insulation material and within 15 degrees of vertical.

Can you vent an entire bathroom with AAV?

Available in different sizes, AAVs can be used to vent an individual fixture, a complete branch, or an entire stack of vents.

Does the AAV go before or after the trap?

Air admittance valves are typically placed between the P-trap of a fixture and the drain line. They're usually mounted on one leg of a sanitary tee, with the other leg going to the drain. The unit must be placed per local codes and the manufacturer's instructions.

How long does an AAV last?

How long does an AAV last? Adeno-associated viruses (AAVs) are stable for several months to years when stored properly at -80°C.

Can a toilet use an air admittance valve?

Yes, an air admittance valve can be used to vent a toilet. This valve is a device designed to allow air to enter the plumbing drainage system to balance the pressure, keeping water from getting pulled out from traps in the plumbing fixtures.

Can an air admittance valve be boxed in?

Air admittance valve installation height

Usually you'll find the installed at the very end of the soil pipe. If you need to, you can install them in line using a soil pipe junction. You'd usually install the air admittance valve within the loft or it is boxed in within the property.

Why should an AAV valve not be fitted outside?

Installing an air admittance valve

Having said that, some air admittance valves are designed for outside use. If that's what you want, check that the valve is kitemarked and rated for outside use in the UK, as a standard valve may not be suitable for frost, freezing temperatures or extreme weather conditions.

What is the difference between an air admittance valve and a cheater vent?

Automatic air vents are spring type devices often referred to as in-line or cheater vents, while air admittance valves have no spring. Air admittance valves are more expensive and are approved in many jurisdictions where in-line and cheater vents are not because of their moving parts (springs).

Does a bathroom sink need an AAV?

AAVs are a great alternative if you can't connect to an existing venting system due to complex pipe routing issues or obstructions – an ideal venting solution for island sinks, remote bathroom groups, home remodels and additions that would otherwise have to be tied into a stack vent utilizing specialized venting ...

What are the rules for air admittance valves?

An AAV requires a free movement of air around the valve to ensure correct and effective operation. If an AAV is installed within a duct or riser it is important that this area is vented. Ventilated grilles or discreet gaps around the boxing may be an option. For further information see NHBC Technical Guidance 8.1/16.

Can I vent a toilet and shower together?

Can my toilet and sink share the same vent? Yes, the toilet and sink can share the same vent, as can the shower.

Is it against code to not have a vent in a bathroom?

Surprisingly, some building codes do not require bathroom fans. All municipalities have different requirements, but some do not draw a hard line on requiring exhaust fans. Bathroom ventilation is needed in those areas, but it can be from a window or fan—you choose.

Are AAV vents legal?

The International Plumbing Code allows AAV's, but that does not help you in your area. AAV's are prohibited in the Uniform Plumbing Code, but perhaps your building department will make an exception if you ask nicely.

How to tell if AAV is failing?

To see if the AAV is working properly, take the valve off and shake - if you shake hard enough you should hear the diaphragm rattling. If you hear no noise the AAV may have failed. Additionally, smelling sewer gas is another sign that the AAV has failed in the open position.

How to vent plumbing without going through the roof?

How to Clear a Clogged Vent Pipe Without Getting on the Roof
  1. Use an Air Admittance Valve (AAV): The valve is installed locally on your plumbing fixture. ...
  2. Garden Hose: Start by inserting the hose into a drain then flushing it out with water pressure. ...
  3. Plumber's Snake: Push through interior drains to reach the vent.

What is the problem with the air admittance valve?

Yes, there are some occasions when a Durgo / air admittance valve failure is possible. They include a) the valve may get stuck and need lubricant to be applied, b) the valve was installed poorly or in the wrong position, or c) the waste pipe is blocked and gases aren't being pushed down properly.

Why is there a fishy smell coming from my bathroom vent?

If your kitchen or bathroom is reeking of fish, despite the lack of fish in that area, this could be an indication of a sewer gas leak, poor water quality or an electrical fault.

What is the minimum height for AAV?

The stack-type AAV shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture being vented. The AAV shall be located within the maximum developed length permitted for the vent.

Previous article
How do you get a higher R-value?
Next article
Who can install an electric oven?