What would cause a blower motor to work intermittently?

Author: scraper  |  Last update: Saturday, August 22, 2026

An intermittent blower motor is a common issue in HVAC systems and vehicles where the fan sporadically stops working, fluctuates in speed, or cuts out entirely. It is most frequently caused by a failing blower motor, a burnt-out resistor, or a bad relay or capacitor.

Why does my blower motor sometimes work and sometimes doesn't?

A faulty resistor or relay can indeed cause the blower motor to stop working or malfunction. "If it only works on high your blower resistor went bad." "The resistor controls how much voltage goes to blower motor. Different fan speeds are different amounts of resistance in the current."

How to tell if blower motor is bad or resistor?

To quickly pinpoint whether the issue is the blower motor or the resistor, check the fan speeds. If the motor only works on the highest setting, or behaves erratically, the resistor is likely bad. If the motor does not work on any speed, the blower motor itself may be failing.

Why is my blower motor turning on and off repeatedly?

A blower motor constantly turning on and off (short cycling) is usually caused by restricted airflow, a failing motor capacitor, overheating, or a bad control board. This strains your system and should be addressed quickly to prevent permanent damage.

Why does my HVAC blower turn on and then off after a few minutes before getting to set temperature?

Common causes include dirty or clogged vents and problems with the draft inducer fan. A faulty pressure switch might cause your furnace to turn on and off irregularly or stop after a few minutes. Fixing this often means cleaning vents or replacing the switch.

3 SIGNS OF A FAULTY BLOWER MOTOR RESISITOR

How to reset blower motor?

Resetting a blower motor typically involves cycling the power, checking for tripped thermal switches, or adjusting your thermostat. These methods apply to residential HVAC systems, though the exact steps vary depending on whether you are working on a furnace, an AC unit, or a car's blower motor.

What are signs of a bad furnace regulator?

The Furnace Won't Ignite: This is the most common and most telling sign. If the gas valve doesn't open, the ignition sequence simply can't begin. Intermittent Heating or Sudden Shutdowns: These unpredictable cycles often point to weak solenoid coils or unstable electrical connections.

How do I get my furnace to stop short cycling?

To fix a furnace that is short cycling (turning on and off rapidly without completing a full heating cycle), first replace your clogged air filter, check that all room registers are open, and ensure the outdoor exhaust vent is clear of debris.

How to check if furnace blower motor is bad?

How do you know if your furnace blower motor is bad

  1. Unusual Noises. Screeching or Squealing. ...
  2. Weak Airflow. Insufficient Heating. ...
  3. Motor Overheating. Excessive Heat from the Furnace. ...
  4. Inconsistent Performance. Start-Stop Issues.

What is the $5000 rule for furnace?

The $5,000 rule is a guideline to help homeowners decide whether to repair or replace their HVAC system. You multiply the age of your unit by the cost of the needed repair. If that number exceeds $5,000, replacing your HVAC system is often more cost-effective.

How do I know if my blower motor relay is bad?

A bad blower motor relay will typically cause your HVAC system to produce no airflow, blow warm air only, or leave the fan running constantly. It often fails due to overheated electrical contacts or melted wiring.

How to bypass your blower motor resistor?

The blower motor resistor can be removed after the bolts have been removed. The wire should be linked to the blower motor's positive terminal, and the negative terminal should be attached to the blower motor's negative terminal. This will turn off the resistor and allow the blower motor to run at full speed.

How to tell if it's the blower motor or resistor bad?

Diagnosing a faulty blower motor versus a bad resistor typically comes down to what fan speeds are working. If the fan only works on the highest setting, the resistor is usually the culprit. If the fan doesn't work on any speed, or if it makes strange noises, the motor itself is likely failing.

Do all blower motors have a reset button?

Most furnaces have a reset button near the blower compartment itself, though the exact location may vary depending on the make and model. It's usually red or yellow and small in size. Consult your furnace manual for guidance if you're unsure where it is.

How much does it cost to replace a blower motor relay?

The average cost for a Blower Motor Relay Replacement is between $109 and $133. Labor costs are estimated between $50 and $73 while parts are priced between $59 and $60. This range does not include taxes and fees, and does not factor in your unique location.

How do I reset my furnace blower motor?

To reset a furnace blower motor, turn off power to the furnace using the emergency switch or the circuit breaker. Wait 2-3 minutes, then locate the red or yellow reset button typically found on the blower motor housing. Press it firmly, and restore power.

What is the life expectancy of a furnace blower motor?

On average, a furnace blower motor lasts between 10 and 20 years. However, this lifespan can be significantly shortened by a lack of maintenance, specifically if air filters are not changed regularly, causing the motor to overheat and overwork.

What is the most common cause of short cycling?

Here are the 10 most common AC short-cycling causes that homeowners face.

  1. Dirty or clogged air filters. ...
  2. Refrigerant leaks and low levels. ...
  3. Oversized air conditioning unit. ...
  4. Electrical problems and faulty wiring. ...
  5. Malfunctioning thermostat. ...
  6. Blocked or restricted airflow. ...
  7. Improper thermostat placement. ...
  8. Frozen evaporator coils.

How to test if furnace is short cycling?

Several signs can indicate furnace short cycling:

  1. Unusual noises, such as rapid cycling or clicking sounds.
  2. Inconsistent heating or if certain rooms feel significantly colder than others.
  3. High heating bills or a constantly running thermostat.

Can a bad blower motor cause short cycling?

Malfunctioning Blower Motor

While less common, a problem with the blower motor can cause a short-cycling furnace. The blower motor works by pushing air through your heating system and sending it out into your home.

How to unstick a propane regulator?

To unstick a propane regulator (often caused by the safety bypass valve tripping), turn off all burner knobs, close the tank valve, disconnect the regulator from the tank for 1–2 minutes to "reset" the pressure, then reconnect and slowly open the tank valve. This process resets the internal mechanism that limits flow.

What is the most expensive thing to fix on a furnace?

The heat exchanger is often considered the most costly part of a furnace to repair or replace. It is a critical component that transfers heat from the combustion process to the air that circulates throughout your home. Over time, heat exchangers can crack due to the constant heating and cooling cycles they undergo.

How do I tell if my furnace control board is bad?

Signs of a failing control board include the furnace not starting, the blower fan running nonstop, flashing error codes on the unit, and the system not responding to the thermostat.