What is the minimum horizontal distance required between vent terminal and window opening of a building?

Author: Robert Thiel  |  Last update: Sunday, May 11, 2025

(1) No vent terminal shall be located directly beneath any door, operable window, or other ventilating opening of the building or of an adjacent building, nor shall any such vent terminal be within 10 ft. horizontally of such an opening unless it is at least 3 ft. above the top of such opening.

How close can a vent pipe be to a window?

Each vent shall terminate not less than 10 feet (3048 mm) from, or not less than 3 feet (914 mm) above, an openable window, door, opening, air intake, or vent shaft, or not less than 3 feet (914 mm) in every direction from a lot line, alley and street excepted.

When venting out the side of a building, what is the minimum horizontal distance you can install the vent pipe from a door or window?

No vent terminal from a sanitary drainage system shall be directly beneath any door, window or other ventilating opening of the same or adjacent building, nor shall any such vent terminal be within 12 feet horizontally of such an opening unless it is at least 3 feet above the top of such opening.

What are the rules for vent pipes?

Tips for Installing Vent Pipes

When installing a revent pipe, the horizontal portion must be at least 6 inches above the fixture's flood level or to the highest point water can rise. For example, the flood level for a sink is its rim or overflow hole.

What is the distance a vent must be above a fixture before turning horizontal?

The vent, which must be sized for the total drainage fixture load of the combination drain and vent system per Section 906.2, can be located anywhere on the system and must rise vertically not less than 6 inches (152 mm) above the flood level rim of the highest fixture being vented before offsetting horizontally.

Plumbing Vent Termination [CPC/UPC Section 906.2]

What is the distance required from any window or opening for the vent pipe on an underground oil tank?

Liquid fuel normal vent pipes shall terminate outside of buildings in a nonhazardous location at a point not less than 2 feet (609.6 mm) measured vertically or horizontally from any building opening and not less than 2 feet (609.6 mm) nor more than 12 feet (3657.6 mm) above the fill pipe terminal.

How far can you run a vent pipe horizontally?

As for the maximum distance between your trap and your vents, that would depend on the actual diameter of the plumbing pipe. If you have 1 ¼-inch pipe, the horizontal distance of the vent should not be more than 30 inches.

What is the code for roof vent pipes?

The International Plumbing Code (IPC), requires plumbing vent pipes to extend vertically at least 152 mm (6 in.) above a roof, per Section 905.5, "Vent Connections and Grades." Additionally, vent pipes must be at least 305 mm (12 in.) away from a vertical surface.

Do horizontal vent pipes need to be sloped?

Vent and branch vent pipes shall be free from drops and sags and be sloped and connected so as to drain by gravity to the drainage system. Every vent shall rise vertically to a minimum of 6 inches above the flood level of the rim of the fixture being served.

Can a vent pipe have a 45-degree angle?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

How much space do you need above a vent?

All furniture, including beds, should be positioned at least 6 to 12 inches away from floor vents to allow for proper airflow into a room.

What is the minimum distance for an exhaust vent from a building opening?

If the manufacturer's instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings.

How close can furnace exhaust be to a window?

The intake and exhaust pipes must be configured at least 5 feet away from each other and away from your home's doors or windows. If you think your furnace pipes may be installed incorrectly, contact an HVAC professional right away as this can mean a costly furnace repair if not attended to immediately.

How close to a window can a flue be?

Distance from windows and doors

The exact distance will depend on the size of your home but, generally, the regulations prevent a boiler flue from being situated within 30-60cm of a window or door. This is to prevent harmful gases from exiting the flue and then re-entering the property through an open door or window.

How far should a soil vent pipe be from a window?

If the soil pipe is less than 3m from a window, ensure that the vent sits at least 900mm above said window or opening. You will also need to make sure that the soil pipe sits a minimum of 200mm above the highest water entry point (aka the highest point where wastewater will reach within a soil pipe).

What is the minimum distance a power vent can be from a lot line for a furnace?

The termination of chimneys or vents equipped with power exhausters shall be located a minimum of 10 feet (3048 mm) from the lot line or from adjacent buildings.

How far can you run B vent horizontally?

The maximum horizontal length of a Type B double-wall connector shall be 100 percent of the height of the chimney or vent except for engineered systems.

Can a toilet, shower, and sink share a vent?

Yes, the toilet and sink can share the same vent, as can the shower. It's common to have one main vent pipe for multiple fixtures, although you might need a larger pipe. You should check with local building and plumbing codes to confirm you'll have adequate piping for your home.

Can plumbing vent pipes have 90 degree angles?

Vent pipes that release sewer gases and maintain proper water pressure may incorporate bends or 90 degree elbows to navigate obstacles and connect to fixtures like sinks.

How far can you run a horizontal vent pipe?

The typical rule of thumb according to code requires you to run a horizontal pipe for no more than one-third of the total length. However, there are exceptions to this building code: If your minimum pipe size is increased by one pipe size, there are no maximum length limitations implied in the system.

What is the rule for roof vents?

A universally accepted guideline for roof ventilation is the 1/150 ventilation rule. According to this rule, a roof must have ventilation that is at least one square foot for every 150 square feet of attic or crawl space. A minimum of 13.3 square feet of ventilation is needed for a 2,000-square-foot attic.

What is the slope of a horizontal vent pipe?

The slope of the vent section of the horizontal branch drain shall be not greater than one unit vertical in 12 units horizontal (8.3-percent slope). The entire length of the vent section of the horizontal branch drain shall be sized for the total drainage discharge to the branch.

How long can a horizontal flue pipe be?

There is currently no maximum or minimum length specified in the building regs. They do say that single skin flue pipe mustn't pass through any roof space, floor or internal wall.

What is the minimum distance you can have from a vent pipe to any window or door opening feet or unless it is at least feet above said opening?

No vent terminal shall be located directly beneath any door, window, or other ventilating opening of a building or of another building, nor shall any such vent terminal be within 10 feet horizontally of such opening unless it is at least 2 feet above the top of such opening.