GWP is expressed as a factor of carbon dioxide where its GWP is equal to 1. The GWP for R-134a refrigerant is 1,430, making it 1,430 times more harmful than carbon dioxide when released into the atmosphere. There are three refrigerants that can be used to replace R-134a: R-1234yf, R-152a, and R-744.
A High-Performing Alternative to R-134a
Opteon™ XL10 (R-1234yf) refrigerant is a non-ozone depleting (ODP) hydrofluoroolefin (HFO) option that meets the industry's growing demands for sustainable, safe, and effective solutions.
Comments Section R600a is a replacement for 134a. It has a smaller molecular weight and can therefore allow an engineer to use a compressor with a lower displacement. It is flammable so engineering of the system requires the electronics and switching to be kept separate from the refrigerant piping.
Years later, R-134a was found to contribute to global warming, and now it too is being phased out . Enter R-1234yf. R-134a and R-1234yf do have many similar properties. That's because R-134a is a hydrofluorocarbon (HFC) while R-1234yf is a hydrofluoro-olefin (HFO) refrigerant.
Refrigerant R513A - Drop-In Alternative for R134a. R513A was developed as a replacement refrigerant for R134a. R513A is a modern, non-flammable refrigerant designed to replace R134a in a wide range of applications. It provides a sustainable solution for both new systems and retrofits.
With the scientific approach to reduce the global warming potential (GWP) of the refrigerant R-134A (i.e. 1430), the refrigerant R-513A with GWP of 631 is the drop-in replacement.
Possible alternatives to R-134a
Attention is increasingly focused on low-GWP refrigerants that are hydrofluoroolefins (HFO). R-1234yf in particular is often seen as a possible alternative to R-134a. The GWP value of R-1234yf is 4, which means it has a very low global warming potential.
According to its manufacturer, Chemours, use of R-1234yf has grown so much since the refrigerant replaced the long-established R-134a that it's now used in 95% of new cars sold in the U.S. An estimated 220 million cars on global roads are also using it.
Why Is R-134A Being Phased Out? When Is the Phaseout Expected to Conclude? Like a lot of '90s relics, R-134A has not aged well. It was known then that 1,1,1,2-tetrafluoroethane could potentially contribute to acid rain and that its ozone layer depletion potential was high.
Internal heat exchanger for R1234yf refrigerant (photo: NRF) As you can see from the above description, R134a and R1234yf refrigerants are not completely identical and their substitution will always result in faster degradation of the A/C system and eventually lead to costly repairs.
A Next-Generation R-134a Refrigerant Alternative
Opteon™ XP10 (R-513A) refrigerant is a non-ozone depleting potential (ODP), low global warming potential (GWP) hydrofluoroolefin (HFO) based replacement for R-134a.
Some notable substitutes for R134a [10] in AAC based on the preceding studies are R1234yf [[11], [12], [13], [14]], R1234z (E) [[15], [16], [17]], R152a [[18], [19], [20]], R290 [21,22], R744 [[23], [24], [25]], R430A [26,27], and R444A [28], etc.
The test results conclude that the blend R134a/R32 at a mass fraction of 85/15 can be a drop-in replacement for R134a refrigerant.
The GWP for R-134a refrigerant is 1,430, making it 1,430 times more harmful than carbon dioxide when released into the atmosphere. There are three refrigerants that can be used to replace R-134a: R-1234yf, R-152a, and R-744.
To accommodate the industry R513A has been tested and approved by Tecumseh as a suitable replacement for R134a. While R513A is a viable option for new and existing equipment, it is not a "drop-in" replacement for R12 or R134a.
The performance of R152a in the domestic refrigerator was constantly better than those of R134a and R32 throughout all the operating conditions, which shows that R152a can be used as replacement for R134a in domestic refrigerator.
Still, the answer is an emphatic, “No.” Not only would a retrofit of this type negate the environmental benefits of R-1234yf, but it would also be a violation of Federal Law under Section 203 of the Clean Air Act: “tampering” with a vehicle's emissions control device.
No, the compressor will fail. These two refrigerants have very different properties. One of R22 and R134a is high pressure and the other is low pressure. They don't mix chemically and don't have the same boiling point, leading to inefficiencies and eventual compressor failure.
R134a has been found to have a lot of greenhouse gas potential, as it can end up in the atmosphere and take forever to break down. For that reason, all new vehicles sold in America after the year 2021 can no longer use this type of refrigerant.
As part of global efforts to reduce the environmental impact of refrigerants, R134a will be phased out by 2025 in favor of more eco-friendly alternatives like R290 and R1234yf12.
RED TEK 12a™ is a second-generation, non-ozone depleting replacement for R-134a and all other non-ozone depleting R-12 substitutes.
The commonly used synthetic refrigerants such as R134a, R407C and R410A have a GWP value higher than 2,500. As a result, their production is being phased out.
“ R-1234yf is an even more environmentally-friendly gas than R-134a and has been making its way into some cars since 2013. MOTOR Selectline.
R134A............
Any HFC refrigerant such as R134A must have POE oil. If there is ant MO present it should be less than 5% or you will have problems. You can use the old CFC refrigerants like R12, R502 and R22 with POE or AB.
The cooling capacity of R1234yf used as a drop-in replacement in a R134a refrigerant facility is about 9% lower than that presented by R134a in the test range. This difference in the values of cooling capacity obtained with both refrigerants decreases when the condensing temperature increases and when an IHX is used.