How to convert R-22 to 410A?

Author: Miss Gladyce Hermann PhD  |  Last update: Sunday, August 31, 2025

If you're going to convert from R22 to R410A refrigerant, the best thing to do would be to flush the lines you have, and put in units, an air handler and condenser that is meant to use R410A. R410A and R-22 are just so different that doing stuff like you want to do won't really work.

Can a R-22 system be converted to R-410A?

You cannot just switch refrigerants because R410-A and R-22 have different chemical properties. R410-A operates at a higher pressure. If you put R410-A into an R-22 system, the parts will rupture due to the increased force.

How much does it cost to convert from R-22 to R-410A?

How much will an R-22 to R-410A conversion cost? The actual cost will depend on many things, including where you live, but most of the time R-22 conversions start at around $2,000 and go up from there. The higher end of that range is somewhere around $4,500 to $4,600.

How to switch from R-22 to 410A?

Although they're both refrigerants, the higher efficiency of R-410A requires an upgrade to the equipment. For example, plan to replace the refrigerant tubing, the evaporator, condenser, and compressor. Other components might also need updates.

Can you use the same line set from R-22 to 410A?

To retrofit an R-22 system with R-410A system your line set must not be more than 25-50 feet in total distance. If the line set is longer than this, you will have to replace the line set with larger lines.

Replacing R22 Refrigerant System With 410A

Do you have to flush R-22 lines for 410A?

When you replace an air conditioner or heat pump and upgrade from R-22 to R-410A, the ideal solution is to replace your refrigerant lines. This is because the mineral oil used in R-22 systems is not compatible with the new R-410A refrigerant and oil.

Can you top off R-22 with 410A?

Never mix R-22 and R-410a.

Can you reuse R-22 pipes for R-410A?

So what the manufacturer recommends, the best option, is if you're going to go from an R22 unit to an R410 unit, that you should have your line set replaced at the same time. So everything is new. There's no contamination, there's no possibility of contamination.

Does R-410A get as cold as R-22?

In fact, R410A can cool a room slightly faster with less energy. Efficient performance is a significant benefit of R410A. However, it works the same way as R22 in absorbing heat to provide cooling. But R410A doesn't make a room any colder than its predecessor.

What would happen if R-410A was added to an R-22 system?

A NJ Tech Explains. The answer: No. Putting R-410A refrigerant into an AC unit that was designed to use R-22 will cause the unit to die soon after it tries to run.

Why is 410A so expensive right now?

Regulatory Changes: As the phase-out continues to restrict production levels and importation, the R-410A price will likely increase. Manufacturing Costs: Fluctuations in the cost of raw materials and manufacturing can also influence the price of refrigerants.

Is 410A being phased out?

As R-410A is phased out, A2L refrigerants are emerging as the primary alternatives due to their lower Global Warming Potential (GWP) and reduced environmental impact. Refrigerants like R-32 and R-454B are leading the charge, offering a GWP that is significantly lower than R-410A.

What is the drop-in replacement for R-410A?

ComStar's RS-53 (R470A) is the world's only drop-in retrofit replacement for existing R410a systems. At 909, RS-53 has a GWP that is effectively 56% lower than R410a. Additionally, RS-51 (R470B) has a GWP of 717 which is 80% lower than R404a, R507 and half of R448A and R449A.

Will a Txv rated for R-22 work with R-410A?

"Hey Dan, do I need to change the TXV valve when switching the outdoor condenser from R-22 refrigerant to R410A?" Yes, you are going to have to change out the TXV. Why? Well, R410A works at a different temperature and a different pressure than R-22. If you don't change it then it's not going to boil off correctly.

Why is R-410A replacing R-22?

R410a has not been known to be ozone-depleting and is proven to be better at absorbing and releasing heat. Air conditioners purchased after 2010 likely already use R410a for its energy efficiency and heightened performance over R-22.

When changing out R-22 equipment to a new R-410A system, the evaporator or indoor coil should be?

When changing out existing R22 equipment to a new R410a system, the evaporator or indoor coil should be: enlarged. This is because R410a systems operate at a higher pressure and generally require larger coil areas to efficiently transfer heat compared to R22 systems.

What are the disadvantages of R-410A?

The chief drawback of R-410A is its Global Warming Potential. While the Montreal Protocol sought to eliminate substances with the potential to deplete the ozone layer, most refrigerants developed in response to the treaty are not altogether environmentally unharmful.

How much does it cost to convert R-22 to R-410A?

The cost to convert a central air conditioner from R-22 to R-410A can range anywhere from $2,000 to over $4,500 in the New Jersey area. The bottom line? If your AC unit is 8+ years old, it's usually not worth the cost to convert and you should just replace the entire R-22 unit with an R-410A unit.

What is the best refrigerant today?

Although there are various types of refrigerants, R-32 is a balanced refrigerant currently receiving attention. Because R-32 efficiently conveys heat, it can reduce electricity consumption up to approximately 10% compared to that of air conditioners using refrigerant R-22.

Can a R-22 system be converted to R-410A?

If you're going to convert from R22 to R410A refrigerant, the best thing to do would be to flush the lines you have, and put in units, an air handler and condenser that is meant to use R410A. R410A and R-22 are just so different that doing stuff like you want to do won't really work.

What freon can I mix with R-22?

When retrofitting an HVAC system, drain all existing refrigerant from the system before adding a new refrigerant. Never mix refrigerants, or "top off" a system running on R-22 with a 400-Series blend.

Can you put a 410A condenser on a R-22 coil?

When it comes to changing out the air conditioning condenser with a non matching r410a, many home owners have questions that they are not finding the correct answer too. At the top of that list is, will it work? The answer is an undeniable and indisputable yes.

What happens if you accidentally put R-22 in a 410A system?

The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur. Mixing refrigerants is not an option either. This will contaminate the system, and the R22 will not evaporate under the higher suction pressure that R410A requires.

Is it illegal to recharge AC with R-22?

As of January 1, 2020, production and import of R22 refrigerant will be illegal in the United States. Of course, continued use of your air conditioner (AC) or heat pump system using R22 refrigerant is allowed.

How much does R-410A cost?

R-410 refrigerant costs $60 per pound on average, but can range from $40 to $75. Keep in mind you cannot purchase R-410A refrigerant without an HVAC pro. As of mid-2024, R-410A refrigerant prices range from $40 to $75 per pound.