How high should Type B vents be above roof?

Author: Caroline Cremin  |  Last update: Friday, January 16, 2026

For example, a 6-inch (152 mm) diameter Type B vent must extend above a simple gabled roof only 1 foot (305 mm) for roofs having up to 6/12 pitch, if the terminal is not within 8 feet (2438 mm) of a vertical surface such as an upper-story exterior wall.

How high should B vent pipe be above roof?

The vent pipe should be run up to a point where the top end is at least a foot or so above the roof.

What is the minimum effective vent height for type B vent?

MINIMUM GAS VENT HEIGHT

A minimum gas vent height of 5 feet above the appliance draft hood is required (see Fig. 8).

How high should vents be above roof?

Extensions of vent pipes through a roof shall be terminated at least 2 feet above the roof surface and shall be properly flashed. Where the roof is used for any purpose other than weather protection, the vent pipe shall extend at least 7 feet above the roof surface and shall be properly supported.

What are the clearance requirements for Type B vent?

A 1-inch clearance (air space) to combustible materials must be maintained, when using DuraVent Round B-Vent, regardless of the pipe diameter. at least 2 feet higher than an adjacent wall or obstruction, if it is within 8 feet.

Gas Venting: Part 1 - Code Requirements for Vents and Chimneys

Is b vent zero clearance?

Yes. Because this is a B-vent, it has zero-clearance to combustibles. We do recommend using 1/2” cement board beneath the unit when building on a wood subfloor.

What is the minimum height for Type B or L gas vent terminations in vertical height above the highest connected appliance draft hood or flue collar?

A Type B or L gas vent shall terminate not less than 5 feet (1524 mm) in vertical height above the highest connected appliance draft hood or flue collar.

How high should vent be?

If you have an electric cooktop, range hoods should typically be 20–24 inches above the heat source. For gas cooktops, your range hood should be around 24–30 inches above the stove. Range hoods are a great way to complement your cooktop or range and can help clear the air while you cook.

What is the minimum vertical termination height of the vent above the roof?

Vent terminals extending through a wall shall terminate at least 6 inches (152 mm) above the roof and the opening shall face upward. Vent terminals shall not terminate under the overhang of the building. Air admittance valves are not approved for venting of plumbing fixture traps.

What is the rule for roof vents?

Your roof vents should be split evenly with half dedicated to air intake and half dedicated for air exhaust. That means that a 2,400-square-foot home with a roof that has a moisture barrier would need 8 square feet of roof vent.

How far can you run B vent horizontally?

The maximum horizontal length of a Type B double-wall connector shall be 100 percent of the height of the chimney or vent except for engineered systems.

What is the minimum height of vent riser?

Vent and branch vent pipes shall be free from drops and sags and be sloped and connected so as to drain by gravity to the drainage system. Every vent shall rise vertically to a minimum of 6 inches above the flood level of the rim of the fixture being served.

What is the height distance requirements for terminating a Type L vent above a roof?

Type L vents shall terminate not less than 2 feet (610 mm) above the highest point of the roof penetration and not less than 2 feet (610 mm) higher than any portion of a building within 10 feet (3048 mm).

What is the height of the B vent termination?

(a) No gas vent shall terminate less than five feet in vertical height above the highest connected equipment draft hood outlet or flue collar. (b) No type B-W gas vent serving a vented recessed heater shall terminate less than twelve feet in vertical height above the bottom of the heater.

What percentage of the total venting should be high on the roof?

Not less than 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not more than 3 feet (914 mm) below the ridge or highest point of the space, measured vertically.

What is the standard height for vent pipes?

A connection between a vent pipe and a vent stack or stack vent shall be made not less than 6 inches (152 mm) above the flood level rim of the highest fixture served by the vent. Horizontal vent pipes forming branch vents shall be not less than 6 inches (152 mm) above the flood level rim of the highest fixture served.

How high does a B vent pipe be above the roof?

For example, a 6-inch (152 mm) diameter Type B vent must extend above a simple gabled roof only 1 foot (305 mm) for roofs having up to 6/12 pitch, if the terminal is not within 8 feet (2438 mm) of a vertical surface such as an upper-story exterior wall.

How high should a roof vent be above the roof?

The vent must extend to a point above the roof; the exact height varies depending on local building codes, but 12 inches is typical. Where the roof serves any purpose other than weather protection (i.e., sun deck), the required height is typically seven feet.

What is the minimum clearance required between a Type B vent and a horizontal or vertical window?

Appliances designed for natural draft venting and incorporating integral venting means shall be located so that a minimum clearance of 9 inches (229 mm) is maintained between vent terminals and from any openings through which combustion products enter the building.

What is the minimum height for air vents?

Vents shall terminate not less than 5 feet (1524 mm) in vertical height above the highest connected appliance flue collar. Exceptions: Venting systems of direct vent appliances shall be installed in accordance with the appliance and the vent manufacturer's instructions.

When should B vent be used?

Type B vents are vents suitable only for listed, draft-hood equipped, gas-fired appliances, including most domestic heating and hot water systems. any appliance that produces flue gasses that exceed 480° F (249° C).

What is the height of vents above fixtures?

3 Vent Connection Height Above Fixtures. Connections between any horizontal vent pipe, including individual vents, branch vents, relief vents, circuit vents or loop vents, and a vent stack or stack vent shall be made at least 6 inches above the flood level rim of the highest fixture on the floor level.

How high above ground should exhaust vent be?

The bottom of the vent terminal shall be located at least 12 inches (305 mm) above finished ground level.

What is the minimum flue height from the floor?

As you can see 4.5 metres minimum flue height is a standard requirement for a stove. The constant flow of flue gases at the correct rate of flow with the least possible variation is required for safe and efficient combustion.

How high does a sure vent need to be?

The Sure-Vent® AAV must be located a minimum of 4 inches above the horizontal branch drain and 6 inches above any insulation material and within 15 degrees of vertical. every structure in which plumbing is installed shall have at least one primary stack vent.