How high should AAV be?

Author: Alexandro Pacocha  |  Last update: Friday, July 4, 2025

How high should you install the air admittance valve? The short answer is a minimum of 200mm above any water entry point. So if you imagine your soil pipe run, then durgo valve / AAV must be fitted above the highest connection to the soil pipe from any sink, bath or toilet that is connected to it.

How high does the AAV need to be?

The AAV should be located a minimum of four inches above the horizontal branch wall tube. » Securing AAV: Measure and cut the PVC pipe appropriately. Solvent-weld the pipe into the adaptor using PVC cement, such as the Oatey® Heavy Duty Clear PVC Cement, which can be used for all PVC pipe and fittings.

What is the minimum height for an air admittance valve?

Air admittance valves are generally placed on a soil pipe that is a minimum of 200mm above the highest water entry point – i.e. the highest point wastewater will reach within a soil pipe.

How high should an air admittance valve be above a trap?

Individual and branch-type AAVs shall not be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented.

Where should AAV be placed?

The AAV should be located: Within the maximum developed length permitted for the vent. A minimum of 4 inches above the horizontal branch drain.

AAV function

What is the downside of the air admittance valve?

The other potential problem with using an AAV instead of a vent pipe is that if you ever get a blockage in the system that prevents the gasses from being pushed down into the sewer, those gases will have nowhere else to go.

What safety level is AAV?

AAV Safety

AAV vectors are biosafety level 1, and consist of recombinant transgene sequences (e.g. marker or human genes) flanked by the AAV inverted terminal repeats.

What height should studor vent be installed?

The Studor valve must be installed a minimum of 4" above the horizontal branch the horizontal branch drain or fixture drain being vented. Studor AAVs must be installed within 15 degrees of the vertical position. Studor valves can be installed below the flood rim level of the fixture.

Why is an S-trap illegal?

The S-Trap's Major Flaw

The “s” design could cause a water siphon, removing the water built up in the curve, opening the seal, and allowing sewer gas to pass through. This flaw is whys-traps are no longer allowed in plumbing code and should be replaced if you have one.

Does the AAV go before or after the trap?

Air admittance valves are typically placed between the P-trap of a fixture and the drain line. They're usually mounted on one leg of a sanitary tee, with the other leg going to the drain. The unit must be placed per local codes and the manufacturer's instructions.

Where are air admittance valves not allowed?

Air admittance valves are not permitted in spaces where pressure conditions adversely affect the valve's operation. They are also not allowed in concealed wall and ceiling spaces used as plenums as part of an air distribution system that is under negative or positive pressure.

What is the life expectancy of an air admittance valve?

Air admittance valves have a typical life expectancy of 20-30 years, so if you start to have issues with sewer gases or smells being released around your sink or in the attic-wherever installed- the air admittance valve could be faulty or failed and should be replaced as soon as possible.

Can you oversize an air admittance valve?

Five DFUs for the bathroom group, three for the washing machine and one for the laundry tub. This example needs an AAV of at least nine DFUs. It is acceptable to oversize an AAV; however, an undersized AAV will not allow the plumbing system to breathe properly.

How high should an internal air admittance valve be installed?

The external soil stack may be terminated below the roofline which reduces the amount of soil pipe and fittings required. The AAV may be installed at a minimum height of 200mm above the highest wet branch connection.

What are the rules for air admittance valves?

The short answer is a minimum of 200mm above any water entry point. So if you imagine your soil pipe run, then durgo valve / AAV must be fitted above the highest connection to the soil pipe from any sink, bath or toilet that is connected to it.

Is P-trap better than S-trap?

While S-traps may still be found in older properties, upgrading to P-traps ensures compliance with modern standards and reduces the risk of sewer gas intrusion. Regular maintenance and professional consultations are key to keeping your bathroom plumbing in optimal condition.

Does an S-trap meet code?

The “S” trap is prohibited under the Uniform Plumbing Code throughout the United States. This is because the “S” trap will siphon or suck water out from the trap which will end up releasing methane (sewer) gases into the home. So, it is a code violation and if you are doing remodeling, you will have to replace it.

Are double P-traps illegal?

Plumbing codes expressly prohibit the use of double traps.

How high should AAV be above trap?

AAV location

It must be located a minimum of 4” above the horizontal branch drain, 6” above any insulation material and within 15 degrees of vertical. AAVs cannot be permanently covered and should be installed in an area that allows air to enter the valve.

What is the height code for an air admittance valve?

Individual and branch air admittance valves shall be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented. Stack-type air admittance valves shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture being vented.

Do air admittance valves fail?

Sometimes you may find that even with an air admittance valve, there are still clogs and a sewer odor. While this is rare, it is possible. Remember that these valves should last anywhere from 20 to 30 years, so if they are only lasting for a couple of years, there may be some problems that need addressing.

Is AAV hazardous?

To date, no human pathology has been associated with AAV infection. On the contrary, a protective role of AAV against human papillomavirus–induced carcinomas,7 as well as induction of antiproliferative gene clusters upon AAV infection, was reported.

What are the limits of AAV?

AAV vector genomes are been limited to 4.7 kb in length in order to balance the need for larger genetic constructs and effective payload delivery. Larger constructs can be attempted to be packaged in AAV vectors, however they are unlikely to be transfected and packaged enough to deliver the intended result.

How do you dispose of AAV?

that come in contact with virus must be disinfected with 10% bleach prior to disposal in biohazard waste container. Autoclave biohazard waste upon completion. Dispose of solid wastes in in orange bags, which are autoclaved and placed in a red biohazard bag/container for final disposal.

Previous article
Do I have a right to privacy in my backyard?
Next article
Why does my furnace turn on but no air?