Does a bathroom vent have to go straight up?

Author: Ms. Ova Hodkiewicz DVM  |  Last update: Wednesday, February 26, 2025

Other venting options includes running the duct up through the roof or down through the soffit. Note that the bathroom vent fan must always exhaust to the outdoors; never allow the duct to simply blow into an attic, crawlspace or other enclosed area.

Does a vent pipe have to go straight up?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

Does a bathroom vent need to be straight?

Ideally the duct run is also straight, with no elbows or turn. Each turn also reduces the CFM. Large bathrooms of bathrooms with separate toilet rooms need multiple fans. You can vent two fans through one roof vent.

Does a bathroom exhaust duct need to be sloped?

The duct should not be crushed or kinked. If possible, the best practice is to have the duct terminal be located on the side wall slightly below the fan, allowing the duct to slope down and away from the fan housing to direct any condensation away from the fan.

Can a vent pipe have angles?

Vents serve your plumbing as well as appliances such as your appliance dryer. Can a vent stack have bends in it? Vent stacks can only have 45-degree angled piping to route horizontal pipe and connect to vertical pipe.

How to Choose a Bathroom Exhaust Fan | Ask This Old House

What is the proper way to vent a bathroom fan?

Bathroom Exhaust Fans
  1. Install the fan to vent outdoors, not into an attic, crawlspace, or space between floors.
  2. Choose a duct with the diameter specified by the fan manufacturer.
  3. Install the duct with the most direct route to the outside with as few bends as possible.

What are the rules for venting plumbing?

In general, the vent should be as close as possible to the fixtures it serves. This proximity helps ensure the vent can effectively equalize air pressure and prevent sewer gas entry. However, there are some common guidelines to consider: The vent should be within 5 to 6 feet of the fixture drain it serves.

Where to position a bathroom vent?

Beyond their location in proximity to water sources, an extractor fan should also be sited as high as possible and as far as possible from the source of the replacement air. In practice, this usually means that the fan should be placed high on the wall opposite the internal door to the bathroom.

Can you use a flex duct for a bathroom exhaust fan?

The most common types ducts that can be used for a bathroom exhaust fan installation are rigid ducting, semi-rigid ducting, flexible ducting or a rigid duct and flexible duct combination.

What happens if a bathroom is not vented properly?

When drain lines aren't properly vented, low pressure inside the pipe can suck water out of the traps, letting sewer gas in. Air pressure imbalances inside the drain pipe can restrict water flow and cause sluggish draining, often mimicking a partial clog inside the pipe.

Can a bathroom vent pipe have an elbow?

Plumbing vents can have elbows and be installed horizontally or at an angle. Properly installed plumbing vents should not leak and prevent slow draining, gurgling sounds, and sewer gas odors.

Can a plumbing vent go sideways?

The good news is that your plumbing vent can indeed be run horizontally.

Does a flue pipe have to go straight up?

First of all, the chimney pipes should be positioned so that they are as vertical as possible. It is important to go through walls or partitions with 45° bends. In addition, horizontal runs and 90° bends should be avoided at all costs, as they cause flue gases and clog the flues.

Can a toilet, shower, and sink share a vent?

Yes, the toilet and sink can share the same vent, as can the shower. It's common to have one main vent pipe for multiple fixtures, although you might need a larger pipe. You should check with local building and plumbing codes to confirm you'll have adequate piping for your home.

What are the requirements for a bathroom vent pipe?

It's typically recommended that you go with a 2" PVC pipe for the vent. This is according to the uniform plumbing code (UPC). It may not be enough, depending on how many fixtures you are trying to run off the vent. You should check with local building code requirements to be on the safe side.

What is code for venting a toilet?

It's typically recommended that you go with a 2" PVC pipe for the vent. This is according to the uniform plumbing code (UPC). It may not be enough, depending on how many fixtures you are trying to run off the vent. You should check with local building code requirements to be on the safe side.

Can a wet vent run horizontally?

A BATHROOM GROUP LOCATED ON THE SAME FLOOR LEVEL MAY BE VENTED BY A HORIZONTAL WET VENT - THE LENGTH OF THE TRAP ARM MUST NOT EXCEED THE LIMITS OF TABLE 1002.2. - THE WATER CLOSET FIXTURE DRAIN CONNECTION MUST BE DOWNSTREAM OF ALL FIXTURE DRAIN CONNECTIONS TO THE HORIZONTAL WET VENT.

What is the code for bathroom fan venting?

Code Requirements for Bathroom Exhaust Fans

Chapter 15 of the International Residential Code (IRC) requires bathrooms and toilet rooms to have a minimum local exhaust capacity of 50 cfm intermittent or 20 cfm continuous.

What are the options for bathroom vents?

The most common option for bathroom exhaust fan venting is the ceiling to wall venting option. The second most common is the roof vent installation. The third most common is probably the vertical wall installation.

Is it better to vent a bathroom fan through the roof or side of the house?

That's why it's fine to have bathroom vents in a basement or lower floors to leave through the side of the home. To help your attic stay clear of mold or mildew, make sure all exhaust fans running through the attic leave through the roof. For one, you'll lessen the chance of the warm air getting back into the attic.

Can a plumbing vent be curved?

In conclusion, while plumbing vents are traditionally designed as straight pipes, bends are permissible under certain conditions. Proper planning, adherence to local building codes, and maintaining the required slope are crucial factors when considering bends in plumbing vents.

Can a wet vent be vertical?

P3108. 4 Vertical Wet Vent Permitted

The vertical wet vent shall be considered to be the vent for the fixtures and shall extend from the connection of the dry vent down to the lowest fixture drain connection.

Do plumbing vents need to be sloped?

Vent and branch vent pipes shall be free from drops and sags and be sloped and connected so as to drain by gravity to the drainage system. Every vent shall rise vertically to a minimum of 6 inches above the flood level of the rim of the fixture being served.

Previous article
Does a kitchen sink drain to a sewer line?
Next article
Can I put down fertilizer and grass seed at the same time?